Burkert Type BBS-25 User Manual
Page 4

8
7. START-UP
WARNING!
Risk of injury from improper operation!
Improper operation may result in injuries as well as damage to the
connection element and the surrounding area.
• Before start-up, ensure that the operating personnel are familiar
with and completely understand the contents of the operating
instructions.
• Observe the safety instructions and intended use.
• Only adequately trained personnel may start up the equipment/the
connection element.
• Following assembly, ensure a controlled restart.
• When starting up the equipment, ensure that no unauthorized volt-
age increases and pressure surges can occur.
NOTE!
Damage to the seals when cleaning the pipeline systems.
• Clean the pipeline systems preferably with a cleaning agent which
does not damage the seals.
• Do not clean the connection elements with wire brushes or
machines which cause abrasion of the surface.
• When using mechanical pipeline monitoring devices, ensure
that they do not damage the sealing elements (also the sealing
contour).
Damaged seals must be replaced!
english
9
8. MAINTENANCE
WARNING!
Danger – high pressure and discharge of medium!
• Before loosening the lock nut or locking clamp, always turn off the
pressure and vent the lines.
• Wear protective equipment if media is hazardous.
• Lock nuts or locking clamps of the connection elements on pres-
surized lines may be retightened only by technicians in consider-
ation of special precautions.
• When shutting down the equipment, ensure that no unauthorized
voltage increases and pressure surges can occur.
• Following maintenance, ensure a controlled restart.
Have the connection elements serviced regularly by technicians!
We recommend a maintenance interval of 6 months.
Inspection and maintenance work includes in particular monitoring and
ensuring the
• leak-tightness,
• identification,
• proper mode of operation of the safety and warning devices.
Opening the screw connection Types BBS-03 and BBS-06
→
Follow safety instructions!
→
Slacken lock nut or lock screws until they can still hold the pipe
ends.
→
Vent the pipe ends slightly and slacken them until they no longer
stick to each other.
→
Remove lock nut or lock screws.
→
Loosen pipe connection.
Opening the clamp connection Types BBS-05 and BBS-25
→
Follow safety instructions!
→
Open wing nut until the locking clamp still holds the pipe
ends.
→
Vent the pipe ends slightly and slacken them until they no longer
stick to each other.
→
Remove locking clamp.
→
Loosen pipe connection.
english
10
9. TRANSPORTATION, STORAGE,
DISPOSAL
NOTE!
Transport damage!
Inadequately protected connection elements may be damaged during
transportation.
• Transport the connection element in a firmly assembled state, pro-
tected against moisture and dirt, in shock-resistant packaging.
• The welding ends must be protected by end caps.
Incorrect storage may damage the connection element.
• Prevent the temperature from exceeding or dropping below the
permitted storage temperature.
• Store the connection element in a dry and dust-free location!
• Store EPDM O-rings and FEP O-rings dry and protected from
UV radiation and for not longer than 3 years.
• Storage temperature -40 to +80°C.
Damage to the environment caused by device components con-
taminated with media.
• Dispose of the device and packaging in an environmentally friendly
manner!
• Observe applicable disposal and environmental regulations.
english