Burkert Type 6624 User Manual
Type 6624 twinpower
english
Type 6624
TwinPower
Supplement
Bistable variant (pulse)
Ergänzungsblatt
Bistabile Variante (Impuls)
Complément
Variante bistable (impulsion)
2/2- and 3/2-way Rocker Solenoid Valve
with Medium Isolation
2/2- und 3/2-Wege Wippen-
Magnetventil mit Medientrennung
Electrovanne à bascule 2/2 et 3/2 voies
avec séparation des fluides
Address / Adresse
Germany / Deutschland / Allemagne
Bürkert Fluid Control Systems
Sales Center
Christian-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: [email protected]
International
www.burkert.com → Bürkert → Company → Locations
© 2013 Bürkert Werke GmbH
Operating Instructions 1306/00_EU-ml_00810310 / Original DE
SYMBOLS
→
designates a procedure which you must carry out.
NOTE!
Warns of damage to property!
Failure to observe the warning may result in damage to
the device or the equipment.
Indicates important additional information, tips and
recommendations.
DARSTELLUNGSMITTEL
→
markiert einen Arbeitsschritt, den Sie ausführen müssen.
HINWEIS!
Warnt vor Sachschäden!
Bei Nichtbeachtung kann das Ventil oder die Anlage
beschädigt werden.
bezeichnet wichtige Zusatzinformationen, Tipps und
Empfehlungen.
SYMBOLES
→
identifie une opération que vous devez effectuer.
REMARQUE !
Met en garde contre des dommages matériels !
L’appareil ou l’installation peut être endommagé(e) en cas
de non-respect.
Désigne des informations supplémentaires importantes,
des conseils et des recommandations d’importance.
This supplementary sheet contains important information for the
use, installation and set-up of the solenoid valve Type 6624,
bistable variant (pulse).
Operating instructions and data sheet for the valve type still apply,
in particular the safety instructions and protective measures.
Magnetic force!
Never bring magnetically sensitive objects near the valve
(e.g. cards with magnetic strip).
A permanent magnet is installed in the valve. The magnetic force is
active even when the valve is switched off.
SET-UP AND INSTALLATION
• Distance between the individual valves: at least. 12 mm
• Distance between valve
and ferromagnetic parts:
at least. 6 mm
(e.g. magnetically conductive housing parts)
If these distances are not observed, the magnetic leakage flux may
cause malfunctions.
• Installation position: any
• Max. shock resistance: 20g
Standard set-up
(≥ 22)
(≥ 22)
≥12
≥12
Alternat. set-up: checkerboard
≥ 1
≥ 1
Overlapping
coils not
permitted!
R ≥ 20
45°
45 ° arrangement, minimum inner
radius for attachment bores
Alternative set-up:
star-shaped
Arrangement for angle X < 45°
≥ 12
X°
ELECTRICAL CONNECTION
• Operating voltage: see rating plate.
• Protection class: 3 according to VDE 0580
• Current pulse length: 100 ... 250 ms
NOTE!
Damage to the valve!
Never simultaneously energize both positive terminals
on the valve. Pulses emitted simultaneously to both
connections will damage the valve.
1
Left connection (+)
(wire: red/black
rectangular connector: white)
2
Middle connection (–)
Negative terminal
3
Right connection (+)
(wire: red
rectangular connector: brown)
Never simultaneously
switch both positive
terminals!
1
2
3
Current pulse 100 - 250 ms
1
+
+
–
2 3
1
+
–
2 3
1
+ –
2 3
3/2-way
NC opened
NO closed
NC closed
NO opened
Damage to
the valve!
2/2-way
closed
opened
FLUIDIC DATA
See rating plate.