Englis h, Turning the actuator – Burkert Type 2712 User Manual
Page 14
12 - EA 2012, 2702, 2712
englis
h
Type
2702
2712
Actuator mm
all
80 - 125
175, 225
DN mm
10 - 65
65 - 100
Unscrew the screw (SW65) above threaded
nipple by ca. half a turn
X
Bring actuator into the desired position
Attention! Valve must be open
X
X
X
Tighten screw with 100 ± 5 Nm
X
Tightening torques for threaded nipple (SW 70)
DN
Tightening torque
[Nm]
65
100
±5
80
120
±5
100
150
±5
Dowel pin
Control cone
Dowel pin
Control cone
Control cone
Control cone
Turning the actuator
See also other documents in the category Burkert Accessories for water:
- Type 0125 (15 pages)
- Type 0121 (4 pages)
- Type 0330 (2 pages)
- Type 0331 (4 pages)
- Type 6012 (4 pages)
- Type 0127 (18 pages)
- Type 0131 (5 pages)
- Type 0141 (5 pages)
- Type 0142 (12 pages)
- Type 0145 (3 pages)
- Type 0174 (5 pages)
- Type 0212 (2 pages)
- Type 0211 (5 pages)
- Type 0212-B (18 pages)
- Type 0250 (64 pages)
- Type 0253 (2 pages)
- Type 0255 (15 pages)
- Type 0355 (2 pages)
- Type 0255 (2 pages)
- Type 8006 (34 pages)
- Type 8640 (2 pages)
- Type 8640 (55 pages)
- Type 8640 (119 pages)
- Type 0256 (15 pages)
- Type 0256 (2 pages)
- Type 0258 (72 pages)
- Type 0262 (5 pages)
- Type 0273 (6 pages)
- Type 0280 (5 pages)
- Type 0280 (2 pages)
- Type 0280 (12 pages)
- Type 0281 (2 pages)
- Type 0282 (2 pages)
- Type 0283 (2 pages)
- Type 0286 (4 pages)
- Type 0287 (15 pages)
- Type 0290 (2 pages)
- Type 0290 (14 pages)
- Type 0293 (18 pages)
- Type 0300 (6 pages)
- Type 0301 (6 pages)
- Type 0311 (2 pages)
- Type 0312 (6 pages)
- Type 6519 (3 pages)
- Type 6519 (4 pages)