beautypg.com

Burkert Type 0353 User Manual

Operating instructions type 0353

background image

Operating Instructions

Type 0353

Design:
3-way solenoid valve, direct acting, normally closed (Circuit
function C), normally open (Circuit function D) or mixer
function (Circuit function E).

Seal Materials and Fluids handled:
See Table1.

Fluid and Ambient Temperature:
See Table 1.

Pressure Range:
Maximum inlet pressure see label on valve.

Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal fillings, seal materials, welding scale etc.).
Installation as required but preferable with coil uppermost.
Installation in this position tends to prevent foreign matter
remaining in core tube (increased life). Do not put any loads
on coil unit.

Type 0353: PTFE tape is recommended for sealing ports.
Mounting is accomplished by means of four M4 x 8 mm
tapped holes located on the valve underside.
Ports are coded on side of body.

Marking (example):

Body Material
BR

=

Brass

SS

=

Stainless Steel

Seal Material
EPDM =

EPDM

NBR

=

NBR

FKM

=

FKM

EF

=

PTFE seat and FKM O-ring

EA

=

PTFE seat and EPDM O-ring

CF

=

FFKM seat and FKM O-ring

NN

=

Neoprene

Circuit Function
C =

3-way - Normally Closed

D =

3-way - Normally Open

E =

Mixer Function

Recorder No.

Voltage / Frequency / Power Consumption

Maximum Pressure

Operating Instructions 0605/08_EU-EN_00893150

Table 1

Seal materials

Fluid

Tempera-
tures [°F]

Buna „N‰
(B)

Ethylene (A)
Propylene

FKM (F)

Neoprene (N)

PTFE (E)

FFKM (C)

Air

Fluid T.

Ambient

+ 14 to + 194
+ 14 to + 130

- 40 to + 212
+ 14 to + 130

+ 14 to + 212
+ 14 to + 130

- 40 to + 266
+ 14 to + 130

- 40 to + 356
+ 14 to + 130

+ 14 to + 266
+ 14 to + 130

Water

Fluid T.

Ambient

+ 50 to + 194
+ 32 to + 130

+ 50 to + 212
+ 32 to + 130

+ 50 to + 212
+ 32 to + 130

+ 50 to + 212
+ 32 to + 130

+ 50 to + 212
+ 32 to + 130

+ 50 to + 212
+ 32 to + 130

Neutral
gas

Fluid T.

Ambient

+ 14 to + 194
+ 14 to + 130

- 40 to + 212
+ 14 to + 130

+ 14 to + 212
+ 14 to + 130

+ 14 to + 356
+ 14 to + 130

+ 14 to + 266
+ 14 to + 130

Light oil

Fluid T.

Ambient

+ 50 to + 194
+ 14 to + 130

+ 50 to + 194
+ 14 to + 130

+ 50 to + 194
+ 14 to + 130

+ 50 to + 194
+ 14 to + 130

LP-gas

Fluid T.

Ambient

+ 14 to + 140
+ 14 to + 130

+ 14 to + 140
+ 14 to + 130

+ 14 to + 140
+ 14 to + 130

+ 14 to + 140
+ 14 to + 130

Steam

Fluid T.

Ambient

+ 212 to + 266

+ 14 to + 130

+ 212 to + 356
+ 14 to + 130

+ 212 to + 266
+ 14 to + 130

Refrigerants

Fluid T.

Ambient

- 40 to + 266
+ 14 to + 130

Voltage 12V or 24V

UL / UR valid with

class 2 power supply only