PUMP OPERATION
This pump is designed to handle dirty water that contains some
solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump
any liquids which may damage the pump or endanger personnel as a result of pump
failure.
Do not operate this pump where explosive vapors or
flammable material exist. Death or Serious injury will result.
TYPICAL MANUAL DEWATERING INSTALLATION
NOTE: Maximum recommended starts should not exceed 10 times per hour.
All S & SX models
are provided with a 33’ (10 m) power cable. NEVER splice the power
cable due to safety and warranty considerations. Always keep the plug end dry.
Note: 230V, single phase and 208V, 230V, 460V & 575V three phase units do not
have a plug and have to be provided separately.
Do not alter the length or repair any power cable with a splice. The
pump motor and cable must be completely waterproof. Damage to the pump or
personal injury may result from alterations.
For manual operation: 115 volt: plug the power cable into any 115 volt grounded
receptacle. 208, 230, 460 & 575 volt: Attach the proper plug, connect directly to the
power source or control box. Check the direction of the rotation. Tilt the pump and start
it. It should twist in the opposite direction of the arrow (on pump). It is recommended
that a Ground Fault Interrupter (GFI) type receptacle (or equivalent) be used.
Single phase pumps always use a three-prong grounded
receptacle. It is recommended that a Ground Fault Interrupter (GFI) type receptacle (or
equivalent) be used.
- SX75CSS-460T SX75CSS-230T SX55CSS-575T SX55CSS-460T SX55CSS-230T SX55CSS-208T SX37CSS-575T SX37CSS-460T SX37CSS-230T SX37CSS-208T SX22CSS-575T SX22CSS-460T SX22CSS-230T SX22CSS-208T SX15CSS-575T SX15CSS-460T SX15CSS-230T SX15CSS-208T SX1500CSS-230 SX750CSS-230 SX750CSS-115 SX08CSS-575T SX08CSS-460T SX08CSS-230T SX08CSS-208T S75C-575T S75C-460T S75C-230T S55C-575T S55C-460T S55C-230T S55C-208T