beautypg.com

Pia-300 pulse isolator, amplifier & splitter – Fill-Rite TM Series Precision Meter User Manual

Page 21

background image

P/No. EL6630

Specifications



Input Signal Device : Hall Effect sensor (pulser)



Max. input frequency : 0 to 5,000 Hz



Power Supply Range : Filtered DC power required,

8-28 VDC maximum
Customer supplied, 250 mA



Idle Current Draw : 0.10 Amps @ 28 VDC



Max. Current Draw,

Both Channels

: 200

mA



Output Signal : 100 mA per channel into
a 0.1

μf

load, sink or source

750’

(230

m)

18-20

AWG

wire



Connections : 2.4

mm

screwdriver

terminals

(wire sizes 14-20 AWG)



Temperature : -40ºF/+158ºF

(-40ºC/+70ºC)



Dimensions : 2.10”

x

0.98”

x

0.38”

52.5

x

24.9

x

9.5

mm



Enclosure options : Local NEMA 3R

Local or remote NEMA 4X
Local or remote NEMA 7/4X

3 . 1

PIA-300 Pulse Isolator, Amplifier & Splitter

(optional component)

The purpose of the PIA-300 is to provide:



Protection and properly interface the signal from the Hall
Effect sensor (pulser) to customer supplied electronics
(totalizer, register, PLC, etc.).



Supply SOURCE signal in place of standard sink.



Amplification of output signal, so it can be transmitted
over greater distances.



Two identical output signals, which can be sent to two
different destinations.

This component can be supplied either unmounted (as an
encapsulated circuit pack), or installed in a variety of option-
al enclosures. In some cases it can be mounted internally in
the remote receiving instrument.

1 ISP-3 INPUT (A)
2 COMMON
3 COMMON
4 LOGIC INPUT (B)
5 PULL UP
6 PROGRAM
7 PROGRAM
8 +8 TO 28VDC
9 +8 TO 28VDC
10

(A)

OUT

11

COMMON

12

COMMON

13

(B)

OUT


The PIA-300 is often used in conjunction with PC58 or
PCDT58 to provide a pulse signal. In those systems, the
PIA-300 can be wired in one of two positions:

A:




B:





A = High frequency, non-scaled pulse signal to the remote
instrument

(raw

meter

signal).


B = Low frequency (max. 8 Hz), scaled pulse signal from
the

register/totalizer

to the remote instrument.

HE

PULSER

PIA

300

PC58

HE

PULSER

PC58

PIA

300