beautypg.com

Optional quadrature signal, Scl wired to emr3 register – Fill-Rite TM Series Precision Meter User Manual

Page 10

background image

1 . 10

Optional Quadrature Signal

When a TM Series flow meter is to be used with an electronic
register requiring dual channel signal (Quadrature signal), the
SCL signal conditioner is used. This produces a simulated
Quadrature signal for the register, which will record volume
correctly, but it does not permit detection of reverse flow.

The SCL is voltage specific. The standard version can be
field selected for 5VDC regulated, or 6-12VDC non-regulated.
An optional version is available for 24VDC service.

The SCL can be mounted:



In a separate enclosure inside the case of the primary
register (such as the EMR

3

electronic register).



In a NEMA 4X enclosure, either mounted on the flow
meter, or installed remote.



In a NEMA 7/4X enclosure, either mounted on the flow
meter, or installed remote.

SCL wired to EMR3 register