DE DIETRICH AWHP-2 MIT-IN-2 iSystem User Manual
Page 26
Code Messages
Description
Checking / solution
B09
BL.SC.IN.OPEN
The BL inlet on the PCU PCB
terminal block is open. Antifreeze
protection.
The contact connected to the BL inlet is open.
4
Contact the professional who takes care of
maintenance of the appliance.
Parameter error.
4
Contact the professional who takes care of
maintenance of the appliance.
Bad connection.
4
Contact the professional who takes care of
maintenance of the appliance.
B10
BL.GROUP.EXT.
Failure outside unit.
4
Contact the professional who takes care of
maintenance of the appliance.
B11
BL.COM SCU
Communication error with the
SCU PCB.
4
Contact the professional who takes care of
maintenance of the appliance.
B12
BL.WATER MIS.
The water pressure is lower than
0,5 bar
Not enough water in the circuit.
4
Top up the installation with water.
B13
BL.DHW. S.
The DHW tank sensor is
disconnected or short circuited
Bad connection.
4
Contact the professional who takes care of
maintenance of the appliance.
B14
BL.OUTSIDE.S
The outside temperature sensor is
disconnected or short circuited.
Bad connection.
4
Contact the professional who takes care of
maintenance of the appliance.
B17
BL.BAD PSU
The parameters saved on the
PCU PCB are impaired.
Parameter error on the PCU PCB.
4
Contact the professional who takes care of
maintenance of the appliance.
B18
BL.BAD PSU
The PSU PCB is not recognised
Wrong PSU PCB for this heat pump.
4
Contact the professional who takes care of
maintenance of the appliance.
B19
BL.NO CONFIG
The inside module has not been
configured.
The PSU PCB has been changed.
4
Contact the professional who takes care of
maintenance of the appliance.
B39
BL.FLOW
Low flow rate.
4
Contact the professional who takes care of
maintenance of the appliance.
B40
BL.FLOW.STOP
Flow rate fault.
4
Contact the professional who takes care of
maintenance of the appliance.
B41
BL.COM.CPT.kWh
Communication error with the
energy meter option PCB.
Bad connection.
4
Contact the professional who takes care of
maintenance of the appliance.
B50
BL.S.DEP.CPT.kWh
Energy meter flow sensor error.
Bad connection.
4
Contact the professional who takes care of
maintenance of the appliance.
B51
BL.S.RET.CPT.kWh
Energy meter return sensor error. Bad connection.
4
Contact the professional who takes care of
maintenance of the appliance.
B52
BL.CPT.kWh.ELEC1
Electical meter ELEC 1 error.
Bad connection.
4
Contact the professional who takes care of
maintenance of the appliance.
B53
BL.CPT.kWh.ELEC2
Electical meter ELEC 2 error.
Bad connection.
4
Contact the professional who takes care of
maintenance of the appliance.
B54
BL.CPT.kWh.THERM
Thermal meter error.
Bad connection.
4
Contact the professional who takes care of
maintenance of the appliance.
B55
BL.FLOW
Low flow rate.
4
Contact the professional who takes care of
maintenance of the appliance.
5. Troubleshooting
AWHP-2 MIT-IN-2 iSystem
25
31/03/2014 - 7616372-001-02