Changing the settings, Setting the set point temperatures, 3 changing the settings – DE DIETRICH AWHP-2 MIT-IN-2 iSystem User Manual
Page 18

User level - Menu #MEASURES
Parameter
Description
Unit
DT INSTALLATION
Installation temperature delta
K
ELEC.ENERGY
(1)
Total electrical energy consumed
kWh
ELEC.ENERG.Y1
(1)
Total electrical energy consumed in the previous year
kWh
ELEC.ENERG.Y2
(1)
Total electrical energy consumed two years ago
kWh
THERM.ENERGY
(1)
Total thermal energy yield
kWh
THERM.ENERG.Y1
(1)
Total thermal energy yield in the previous year
kWh
THERM.ENERG.Y2
(1)
Total thermal energy yield two years ago
kWh
(1) The parameter is only displayed for the options, circuits or sensors actually connected.
4.3
Changing the settings
4.3.1.
Setting the set point temperatures
To set the various heating, DHW and swimming pool temperatures,
proceed as follows:
1. Press the C key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button.
To go back to the previous display, press the key j.
4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.
To cancel, press key h.
Menu C
Parameter
Adjustment range Description
Factory setting
DAY TEMP.A
5 to 30 °C
Desired room temperature in comfort periods on circuit A
20 °C
NIGHT TEMP.A
5 to 30 °C
Desired room temperature in reduced periods on circuit A
16 °C
ROOMTEM.COOL A
(1)
(2)
22 to 30 °C
Desired room temperature set point in cooling mode
25 °C
DAY TEMP.B
(2)
5 to 30 °C
Desired room temperature in comfort periods on circuit B
20 °C
NIGHT TEMP.B
(2)
5 to 30 °C
Desired room temperature in reduced periods on circuit B
16 °C
ROOMTEM.COOL B
(2)
(1)
22 to 30 °C
Desired room temperature set point in cooling mode
25 °C
DAY TEMP.C
(2)
5 to 30 °C
Desired room temperature in comfort periods on circuit C
20 °C
NIGHT TEMP.C
(2)
5 to 30 °C
Desired room temperature in reduced periods on circuit C
16 °C
ROOMTEM.COOL C
(2)
(1)
22 to 30 °C
Desired room temperature set point in cooling mode
25 °C
DHW TEMP.
(2)
10 to 65 °C
Desired domestic hot water temperature in the DHW circuit 55 °C
(1) The parameter is only displayed if the corresponding circuit can handle cooling.
(2) The parameter is only displayed for the options, circuits or sensors actually connected.
MODE
C002266-A
4. Operating the appliance
AWHP-2 MIT-IN-2 iSystem
17
31/03/2014 - 7616372-001-02