Technical specifications, Characteristics of the appliance, 7 technical specifications – DE DIETRICH TWH 200E - TWH 300E - TWH 300EH User Manual
Page 29: 1 technical specifications

7 Technical specifications
7.1
Technical specifications
7.1.1.
Characteristics of the appliance
Model
TWH 300 E
TWH 300 EH
TWH 200 E
Capacity
litres
270
265
215
Output (HP) -Air temperature = 15°C
W
1700
1700
1700
Absorbed electrical power (HP)
W
500
500
500
COP
(1)
3.7
3.6
3.5
COP
(2)
2.94
2.75
2.90
Air flow rate - maximum
m
3
/h
385
385
385
Nominal air flow rate (DP = 25 Pa)
(2)
m
3
/h
320
320
320
Electrical resistor output
W
2400
2400
2400
Operating pressure
bar (MPa)
10
10
10
Power supply voltage
V
230
230
230
Circuit breaker
A
16
16
16
Exchanger surface
m
2
-
1.00
-
Continuous output DT = 35 K
(3)
(4)
litres per hour
-
955.6
-
Flow rate over 10 minutes with DT = 30 K
(3)
l/10 mm
-
420
-
Heating time (15-51 °C)
(1)
Hours
7
7
5
Qpr
(1)
kWh/24h
0.67
0.75
0.73
V40
(1)
litres
357
358
240
Vmax
(2)
litres
388
383
281.9
Pes
(2)
W
34
36
30
Maximum length of the air connection Diameter 160 mm
(5)
m
25
25
25
R134a refrigerant
kg
1.45
1.45
1.45
Weight (empty)
kg
105
123
92
(1) Value obtained at an air temperature of 15°C and a relative humidity of 70%. Water inlet temperature at 15°C in accordance with EN255-3.
(2) Value obtained with an air temperature of 7 and a water inlet at 10 °C, as per EN16147 based on Specification LCIE N°103-15/B:2011
(3) Domestic cold water input at 10°C - Primary inlet temperature at 80°C
(4) Output: 34.1 kW
(5) The installation of suction and backflow conduits on the heat pump lessens its performance
TWH 200E TWH 300E TWH 300EH
7. Technical specifications
03/02/2014 - 7605313-001-02
28