7 Technical specifications

7.1

Technical specifications

7.1.1.

Characteristics of the appliance

Model

TWH 300 E

TWH 300 EH

TWH 200 E

Capacity

litres

270

265

215

Output (HP) -Air temperature = 15°C

W

1700

1700

1700

Absorbed electrical power (HP)

W

500

500

500

COP

(1)

3.7

3.6

3.5

COP

(2)

2.94

2.75

2.90

Air flow rate - maximum

m

3

/h

385

385

385

Nominal air flow rate (DP = 25 Pa)

(2)

m

3

/h

320

320

320

Electrical resistor output

W

2400

2400

2400

Operating pressure

bar (MPa)

10

10

10

Power supply voltage

V

230

230

230

Circuit breaker

A

16

16

16

Exchanger surface

m

2

-

1.00

-

Continuous output DT = 35 K

(3)

(4)

litres per hour

-

955.6

-

Flow rate over 10 minutes with DT = 30 K

(3)

l/10 mm

-

420

-

Heating time (15-51 °C)

(1)

Hours

7

7

5

Qpr

(1)

kWh/24h

0.67

0.75

0.73

V40

(1)

litres

357

358

240

Vmax

(2)

litres

388

383

281.9

Pes

(2)

W

34

36

30

Maximum length of the air connection Diameter 160 mm

(5)

m

25

25

25

R134a refrigerant

kg

1.45

1.45

1.45

Weight (empty)

kg

105

123

92

(1) Value obtained at an air temperature of 15°C and a relative humidity of 70%. Water inlet temperature at 15°C in accordance with EN255-3.

(2) Value obtained with an air temperature of 7 and a water inlet at 10 °C, as per EN16147 based on Specification LCIE N°103-15/B:2011

(3) Domestic cold water input at 10°C - Primary inlet temperature at 80°C

(4) Output: 34.1 kW

(5) The installation of suction and backflow conduits on the heat pump lessens its performance

TWH 200E TWH 300E TWH 300EH

7. Technical specifications

03/02/2014 - 7605313-001-02

28