6 Troubleshooting

6.1

Messages (Code type bxx or Exx)

6.1.1.

Messages (type code

bXX)

In the case of failure, the control panel displays a message and a

corresponding code.
1. Make a note of the code displayed.

The code is important for the correct and rapid diagnosis of the

type of failure and for any technical assistance that may be

needed.

2. Disconnect and reconnect the mains cable.

The appliance will restart only when the malfunction has been

corrected.

3. If the code is displayed again, correct the problem by following the

instructions in the table below:

Code no. Description

Checking / solution

B00

Parameter error on the PCU PCB

Reset the parameters.

¼See chapter: "Return to the factory settings",

page 21

.

B01

Pressure switch alarm

Note: DHW production is handled by back-up if back-up

enabled

4

Contact the professional who takes care of

maintenance of the appliance.

B02

Maximum DHW temperature exceeded

Note: DHW production is not covered (by the compressor

or the back-up)

4

Contact the professional who takes care of

maintenance of the appliance.

B03

The room temperature is higher than 35°C. The

compressor is outside its operating range.

Note: DHW production is handled by back-up if back-up

enabled.

4

Modify the parameters according to the instructions

in the manual.

4

The compressor will handle DHW production once

the room temperature is less than 35°C.

B04

The room temperature is less than -5°C.

Note: DHW production is handled by back-up if back-up

enabled.

4

Modify the parameters according to the instructions

in the manual.

4

The compressor will handle DHW production once

the room temperature is higher than -5°C.

B25

The bottom DHW temperature sensor is short circuited

4

Contact the professional who takes care of

maintenance of the appliance.

B26

The bottom DHW temperature sensor is open

4

Contact the professional who takes care of

maintenance of the appliance.

B27

The top DHW temperature sensor is short circuited

4

Contact the professional who takes care of

maintenance of the appliance.

B28

The top DHW temperature sensor is open

4

Contact the professional who takes care of

maintenance of the appliance.

TWH 200E TWH 300E TWH 300EH

6. Troubleshooting

03/02/2014 - 7605313-001-02

24