Datamax-O'Neil Workstation series Programmer’s Guide User Manual
Page 46

1 | Programmer’s Guide
Thermal Printer Programmer’s Guide
40
COPIES
7
The number of copies of each
label for a print job
1 – 9999
1
PORTNUMBER
The TCP port number
0 - 65535
9100
DISKLOCK
Prevents writing to user flash
OFF, ON
OFF
GPIO
Enables use of external GPIO
device
OFF, MODE1
OFF
HEXTRANSFERMODE
Enables Hex Transfer mode
OFF, ON
OFF
GPIOSIGNALTYPE1
Selects the type of input/output
signal for pin 1
LOW, HIGH, LOWPULSE,
HIGHPULSE, EDGE
LOW
GPIOSIGNALTYPE2
Selects the type of input/output
signal for pin 2
LOW, HIGH, LOWPULSE,
HIGHPULSE, EDGE
LOW
GPIOSIGNALTYPE3
Selects the type of input/output
signal for pin 3
LOW, HIGH, LOWPULSE,
HIGHPULSE, EDGE
LOW
GPIOSIGNALTYPE4
Selects the type of input/output
signal for pin 4
LOW, HIGH, LOWPULSE,
HIGHPULSE, EDGE
LOW
GPIOSIGNALTYPE5
Selects the type of input/output
signal for pin 5
LOW, HIGH, LOWPULSE,
HIGHPULSE, EDGE
LOW
GPIOSIGNALTYPE6
Selects the type of input/output
signal for pin 6
LOW, HIGH, LOWPULSE,
HIGHPULSE, EDGE
LOW
GPIOSIGNALTYPE7
Selects the type of input/output
signal for pin 7
LOW, HIGH, LOWPULSE,
HIGHPULSE, EDGE
LOW
GPIOSIGNALTYPE8
Selects the type of input/output
signal for pin 8
LOW, HIGH, LOWPULSE,
HIGHPULSE, EDGE
LOW
GPIOSIGNALNAME1
Selects the function of pin 1
SOP, REPRINT, SLEW,
PAUSE, EOP, READY,
MEDIALOW, SERVICE
SOP
GPIOSIGNALNAME2
Selects the function of pin 2
SOP, REPRINT, SLEW,
PAUSE, EOP, READY,
MEDIALOW, SERVICE
REPRINT
GPIOSIGNALNAME3
Selects the function of pin 3
SOP, REPRINT, SLEW,
PAUSE, EOP, READY,
MEDIALOW, SERVICE
SLEW
GPIOSIGNALNAME4
Selects the function of pin 4
SOP, REPRINT, SLEW,
PAUSE, EOP, READY,
MEDIALOW, SERVICE
PAUSE
GPIOSIGNALNAME5
Selects the function of pin 5
SOP, REPRINT, SLEW,
PAUSE, EOP, READY,
MEDIALOW, SERVICE
EOP
GPIOSIGNALNAME6
Selects the function of pin 6
SOP, REPRINT, SLEW,
PAUSE, EOP, READY,
MEDIALOW, SERVICE
READY
GPIOSIGNALNAME7
Selects the function of pin 7
SOP, REPRINT, SLEW,
PAUSE, EOP, READY,
MEDIALOW, SERVICE
MEDIALOW
Variable
Description
Range
Default