Datamax-O'Neil Workstation series Programmer’s Guide User Manual
Page 25
![background image](/manuals/327569/25/background.png)
Programmer’s Guide | 1
19
Thermal Printer Programmer’s Guide
insure every resident barcode produced by Datamax-O'Neil Barcode Printers are within
industry specification. Upon deciding to modify these values, be aware that some
barcode scanners may not be able to property decode the barcode. Also note that any
modified values are not stored permanently in the printer. Once the job of labels has
completed, the default values are restored.
Table 6: Barcode Defaults
Barcode
ID
Barcode Description
Narrow Element
Width
Default
Ratio
Default Height
Dots
Decipoints
Dots
Decipoints
1000
(Default)
Code 3 of 9
4
9.6
3:1
150
360
1001
Code 3 of 9 Extended
4
9.6
3:1
150
360
1010
UPC A
4
9.6
N/A
300
720
1020
UPC E
4
9.6
N/A
300
720
1021
UPC/EAN Add-On
4
9.6
N/A
300
720
1030
Code 128 Auto Select
3
7.2
N/A
150
360
1031
Code 128 Set A
3
7.2
N/A
150
360
1032
Code 128 Set B
3
7.2
N/A
150
360
1033
Code 128 Set C
3
7.2
N/A
150
360
1040
EAN 8
4
9.6
N/A
240
576
1050
EAN 13
4
9.6
N/A
300
720
1060
Interleaved 2 of 5 Mod 10
3
7.2
3:1
150
360
1061
Interleaved 2 of 5 Bearer
Bars
3
7.2
3:1
150
360
1062
Interleaved 2 of 5
3
7.2
3:1
150
360
1070
GS1-128
4
9.6
N/A
450
1080
1080
Codabar
3
7.2
N/A
150
360
1090
UK Plessey
3
7.2
N/A
150
360
1091
MSI Plessey Mod 10
3
7.2
N/A
150
360
1100
Code 93
3
7.2
N/A
150
360
1110
HIBC Code 39
3
7.2
N/A
150
360
1111
HIBC Code 128
3
7.2
N/A
150
360
1120
Telepen
3
7.2
N/A
150
360
1130
GS1 Databar (linear only)
3
7.2
N/A
141
338.4
1131
GS1 Databar Expanded
(linear only)
3
7.2
N/A
144
345.6
1500
Postnet
6
14.4
N/A
38
91.2
1510
Planet
6
14.4
N/A
38
91.2
1520
FIM
9
21.6
N/A
187
448.8