8. Troubleshooting

Test Method 2

Note:

This method is only for advanced

troubleshooting by service technicians.

This shows all information sent to the

printer in hex-code and the function is

used to determine possible

communication faults, since it is possible

to see exactly what data the printer

receives.

1.

Switch off the printer.

2.

Press the print button, but do not

release it.


3.

Switch on the printer without releasing

the print button.


4.

Release the print button when the

printer starts printing.

The printer starts by printing information

as in test method 1. It then stops and will

continue printing once the data is sent to

the printer. By checking the received data,

you can determine whether character

received agree with the Label point-

commands and the transferred ASCII-

characters.

Differences between the received signals

and the transferred characters may be due

to incorrect parameters (e.g. Baud rate) or

the presence of electrical inference during

the transfer. Check the communication

cable, the length of the cable and whether

or not the cable is close to power cables.

Cancelling Test Methods

To cancel the test methods, turn the

printer off and wait 15 seconds before

switching it on again.