11

3.2.3 Dip Switch Functions

Table 2 shows the available dip switch settings.

Table 2 – DIP Switch Setting

Dip

Switch

Function

Switch #

Switch

#

Switch

#

Notes

1 & 2

Communication Interface

SW 1

SW 2

RS232

OFF

OFF

Baud rate set by Dip switches 3,4 and 5

IrDA

ON

OFF

Baud Rate can be negotiated up to the

value specified through Dip switches 3,4

and 5

Bluetooth

OFF

ON

802.11g

OFF

ON

3 & 4 & 5

Baud Rate

SW 3

SW 4

SW 5

115200

OFF

OFF

OFF

57600

ON

OFF

OFF

38400

OFF

ON

OFF

19200

ON

ON

OFF

14400

OFF

OFF

ON

9600

ON

OFF

ON

Use for fixed IrDA

2400

OFF

ON

ON

1200

ON

ON

ON

6

Parity Bit

SW 6

Parity Enabled

ON

Does not apply for IrDA

Parity Disabled

OFF

Does not apply for IrDA

7

Odd/Even

SW 7

Even Parity Checker

ON

Does not apply for IrDA

Odd Parity Checker

OFF

Does not apply for IrDA

8

Auto Power Save

SW 8

Power Save Disabled

OFF

Manual On/Off

Power Save Enabled

ON

Auto Power Down

Note: In order for changes to the dip switch configuration to take effect, the printer power must be
reset. This action occurs automatically when the battery is removed to gain access to the dip
switches. Please refer to the Developer’s Manual for more information