Datamax-O'Neil APEX 2 User Guide User Manual
Page 15
11
3.2.3 Dip Switch Functions
Table 2 shows the available dip switch settings.
Table 2 – DIP Switch Setting
Dip
Switch
Function
Switch #
Switch
#
Switch
#
Notes
1 & 2
Communication Interface
SW 1
SW 2
RS232
OFF
OFF
Baud rate set by Dip switches 3,4 and 5
IrDA
ON
OFF
Baud Rate can be negotiated up to the
value specified through Dip switches 3,4
and 5
Bluetooth
OFF
ON
802.11g
OFF
ON
3 & 4 & 5
Baud Rate
SW 3
SW 4
SW 5
115200
OFF
OFF
OFF
57600
ON
OFF
OFF
38400
OFF
ON
OFF
19200
ON
ON
OFF
14400
OFF
OFF
ON
9600
ON
OFF
ON
Use for fixed IrDA
2400
OFF
ON
ON
1200
ON
ON
ON
6
Parity Bit
SW 6
Parity Enabled
ON
Does not apply for IrDA
Parity Disabled
OFF
Does not apply for IrDA
7
Odd/Even
SW 7
Even Parity Checker
ON
Does not apply for IrDA
Odd Parity Checker
OFF
Does not apply for IrDA
8
Auto Power Save
SW 8
Power Save Disabled
OFF
Manual On/Off
Power Save Enabled
ON
Auto Power Down
Note: In order for changes to the dip switch configuration to take effect, the printer power must be
reset. This action occurs automatically when the battery is removed to gain access to the dip
switches. Please refer to the Developer’s Manual for more information