Balancing function
6 - 5
Additional functions
By pressing the key, the additional functions bar displays the functions available in
the unbalance measurement page of the balancing function:
allows access to the calibration values for the current balancing (see 6 – 6
Calibration procedure).
The guided procedure starts automatically at the first step yet to be carried
out, or the last step (in the event that they have already been completed).
opens the balancing records (see next paragraph).
quits the current balancing operation and starts a new calibration procedure
(see 6 – 6 Calibration procedure).
Displaying balancing results from the records
Balancing results loaded from the records are displayed in a special screen laid out as
follows:
1. position number in the balancing record
2. date and time saved
3. synchronous filter width
4. value (in U units) and angular position of the initial unbalance on plane P1
5. value (in U units) and angular position of the final unbalance on plane P1
6. value (in U units) and angular position of the initial unbalance on plane P2
7. value (in U units) and angular position of the final unbalance on plane P2
8. rotation velocity of the rotating body
1
3
2
4
5
6
7
8