2 - self-calibration – CEMB USA C72_2SE (B) User Manual
Page 22

I 0226 - 22
GB
6.2 - SELF-CALIBRATION
For machine self-calibration proceed as follows:
- Fit a medium-sized metal wheel on the shaft. Example: 6” x 14” (± 1”)
- Preset the exact dimensions of the wheel mounted.
CAUTION!!
Presetting of incorrect dimensions would mean that the machine is not correctly
calibrated, therefore all subsequent measurements will be incorrect until a new self-
calibration is performed with the correct dimensions!
- Perform a spin under normal conditions.
- Add 100 g (3.5 oz) on the outside in any angular position.
- Shift the 100 g. weight from the outside to the inside keeping
the same angular position.
- Shift the 100 g. weight to the 12 o’clock position.
END OF SELF-CALIBRATION
CANCELS SELF-CALIBRATION IN ANY PHASE