5.3 - RECALCULATION OF THE UNBALANCE
Press
after new setting of the measurement
5.4 - RESULT OF MEASUREMENT
Fig. 13
Inside correction
Outside correction
After performing a balancing spin, the amounts of unbalance are shown on the digital readouts.
When the matrix display is ON, this indicates the correct angular wheel position for fi tting
counterweights. (12 o’clock position). When the beep signal is enabled (see section
CONTROL
OF THE FUNCTIONS MENU
), this is activated when the wheel reaches the correction position.
If the unbalance is less than the threshold selected,
is displayed instead of the unbalance, with
it
is possible to read the values below the threshold chosen gram by gram.
If the static unbalance is greater than 30 gr., the OPT Led fl ashes to suggest an unbalance optimisation
operation. (see
UNBALANCE OPTIMIZATION)
5.4.1 - INDICATION OF EXACT CORRECTION POSITION IN ALU-S
In correction mode ALU-S it is possible to cancel approximations in the mounting of
the counterweights by proceeding as follows:
- press
- Insert the correct weight on the relative seat on the weight holder pincers
- Remove the gauge when the display shows:
to indicate that the gauge should be pulled further out
to indicate that the gauge should be returned to rest position
The left display gives the indications for reaching the position regarding the inside, while the right display
that of the outside
The position of the gauge is also indicated by the position repeater Led (8).
Position
reached on
the internal
side