beautypg.com

Total access 1200 quad ima module with subtending – ADTRAN 1200 User Manual

Page 2

background image

PRICING AND AVAILABILITY 800.827.0807

TECH SUPPORT 800.726.8663

RETURN FOR REPAIR 256.963.8722

www.adtran.com

61179611L2-22C

Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.

Warranty information can be found at

www.adtran.com/warranty

. U.S. and Canada customer Faxback: 877-457-5007, Document 414.

Total Access 1200 Quad IMA Module with Subtending

FRONT PANEL LEDS

T1/E1

{

Off.................................. Facility Unassigned

z

Green.............................. All Good, IMA in Sync

Green (Flashing) ............ T1/E1 OK, no IMA sync

z

Yellow............................ Signal Present, OFF

Yellow (Flashing) .......... T1 is in loopback

z

Red..................................No Signal

ETH

z

Green...............................Ethernet Signal Present

Green (Flashing) ............ Ethernet with traffic

z

Red................................. No Signal

SUB IN

z

Green...............................Connected to an Upstream Box

Green (Flashing) ............ Connected with traffic

{

Off.................................. Not connected

SUB OUT

z

Green.............................. Connected to an Downstream Box

Green (Flashing) ............ Connected with traffic

{

Off.................................. Not connected

COMPLIANCE

This product is NRTL listed to the applicable UL standards. This product is intended to be installed in
a Type “B” or “E” enclosure in a Restricted Access Only area. The Total Access 1200 shelf Frame

Ground terminal must be connected to and earth ground.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any

interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by ADTRAN could void the user’s authority to

operate the equipment

PROVISIONING

The Total Access 1200 has a front panel mounted DB–9 connector that supplies an RS–232 interface
for connection to a controlling terminal. The supported terminal type is VT100 or compatible and is
set for 9600 baud, 8 data bits, no parity, and 1 stop bit.
At the Total Access 1200 Login screen, enter the case sensitive account name and password. Note the
the default login is ADMIN and the password is PASSWORD,

and can be changed upon initial

login.

NOTE: To traverse through the menus, select the desired entry, and press

E

NTER

. To work

backward in the menus, press

E

SC

.

Code

Input

Output

Power Code

F

C

Telecommunication Code (TC)

C

X

Installation Code (IC)

A

V

Provisioning Options

Upon initial installation, the module will be provisioned according to factory default settings as show in
the table below. Use the menu screens to make changes as required. The complete menu tree and
provisioning steps are available in the Installation and Maintenance Practice (P/N 61179611L2-5)

Provisioning Options

Settings (Defaults in Bold)

PVCs

User definable; Each ADSL connection must have at least one PVC/PVP for proper
operation (No Default)

Traffic Descriptors

UBR; CBR; VBR–rt; VBR–nrt

Subtend Configuration, mode

Enabled (Master); Disabled (Slave)

T1 Provisioning Options

T1 Type

DSX; T1

T1 Framing

ESF; SF

T1 Line Code

B8ZS; AMI

T1 Line Build Out

DSX Type: 0-133 ft.; 133-266 ft.; 266-399 ft.; 399-533 ft.; 533-655 ft;
T1 Type: 0 dB; –7.5 dB; –15 dB;–22.5 dB

IMA Facility (1-4)

IMA_Group; Pass-through; Unassigned

IMA Transmit ID

0-255 (1 default)

IMA Transmit Frame Length

32; 64; 128; 256

Minimum Tx Active Links

1-4

Minimum Rx Active Links

1-4

Maximum Link Diff Delay

0-100

Group Operation Mode

In Service; Out of Service-Maintenance; Out of Service - Unassigned

ADSL Options

Card Service State

In Service; Out of Service-Maintenance; Out of Service - Unassigned

Line Service State

In Service; Out of Service-Maintenance; Out of Service - Unassigned

Service Mode

Multimode; T.413, G.dmt; G.lite

Link Down Alarm

Disabled; Enabled

Rate Mode

Fixed; Rate Adaptive

Line Type

Interleave; Fast

Target SNR Margin

0-15 dB (6 dB default)

Max SNR Margin

0-31 dB (9 dB default)

Min SNR Margin

0-31 dB

Fast Max Tx Rate
Fast Min Tx Rate

32-8160 kbps Downstream
32-896 kbps Upstream

Interleave Max Tx Rate
Interleave Min Tx Rate

32-7616 kbps Downstream
32-896 kbps Upstream

Interleave Max Delay

5-255 ms (5 ms default)

LOS Secs

0-900 (0 = Disabled)

ES Secs

0-900 (0 = Disabled)