Save configuration, 14 configuration – MoTeC VCS User Manual
Page 18
14 Configuration
7. Enter GaugeId to determine on which gauge the channel will be
displayed.
Gauge Id List
1
Speed
2
RPM
4
Gear
5
Throttle
6
Lateral
G-force
7
Longitudinal G-force
8
Lap
Distance*
9
Brake
Pressure
10
Limiter*
11
Steered
Angle
12
Internal
Voltage*
13
Lap
Time
14
Lap
Number
15
Last
Lap
* currently not displayed
8. Enter the recording start and stop settings in the Event 1 and Event 2
conditions.
The recording can be started or stopped when the sensor value is
equal (=), greater (>) or smaller (<) than any entered value for a set
time.
Note: Ensure that there are no clashing start and stop conditions. For
example, the VCS will not record if the conditions to start and stop are
set at the same time.
To ensure all CAN messages are correctly received, the CAN receive settings
must match the settings from the transmitting device. When using a MoTeC
Data Logger or ECU for transmitting, the sections Configure a MoTeC Data
Logger and Configure a MoTeC 'hundred series' ECU will explain this further.
Save Configuration
When all settings are finalised, click Save As to save the configuration file.
The configuration file must be sent to the VCS recorder before the changes
take effect. See Sending and Retrieving Configuration Files.