2: Retrofit Cover Assembly Installation Instructions:
1) Open existing cover or lid assembly and discard.
2) Remove existing bulb and reflector assembly and discard per federal requirements. When cutting the existing
wire connections, be sure to maximize the length remaining with the lower unit.
3) Manufacturer recommends but does not require the removal of existing ballast, transformer, and capacitor
assemblies from existing unit.
4) Place new Retrofit Cover Assembly upside down adjacent to existing lower unit. Inspect existing gasket and
replace with new gasket if required. Connect ground strap wire (provided) to existing fixture ground location.
5) Using
Gel Filled Wire nuts connect ground pigtail (supplied) and input wires from power supply (supplied) to cut
incoming power feeds on existing lower unit.
6) Connect Black wire from Power Supply to Line, Connect White wire from Power Supply to Neutral, and connect
Ground pigtail (supplied) to input ground wire.
7) Place Retrofit Cover Assembly over existing lower unit insuring wires are not pinched during installation. Insure
LED light faces the sign structure. Align rear hinge clips with bosses in lower fixture and place retrofit cover down
onto lower assembly.
8) Loosen front, side nuts on front top side clips until they fall down below the side flange on the lower housing, then
tighten nut and secure cover assembly to lower fixture
9) Loop safety strap around nearest rigged structure or rigged conduit entry