BatteryMINDer 28252-AA-Series User Manual
Page 26

Rev. I-100511
Page 2
P/N VDC28252-AA-Series-MNL
BatteryMINDer
®
Model 28252-AA-Series
Aviation charge mode output control: Factory Presets (defaults)
NORMAL
TOLER
-
ANCE
UNIT
Soft start charging activity conditions:
Battery voltage is between 6-22
±2%
Vdc
Soft start charging output current control:
6.25
±10%
Adc
Soft start mode transits to bulk mode:
Battery voltage is above 22
±2%
Vdc
Soft start charging time limit: stops charging
6
±10%
Hours
Bulk charging condition:
Battery voltage is above 22
±2%
Vdc
Bulk charging current control:
25
±10%
Adc
Bulk mode transits to Absorption mode:
Battery voltage above 28.2
1
±1%
Vdc
Max. Bulk Charging Time Limit: (Stops charging if time is exceeded)
15
±10%
Hours
Absorption charging activity:
Battery voltage above 28.2
1
±1%
Vdc
Absorption charging output voltage control:
Battery voltage is constant at 28.2
1
±1%
Vdc
Max. Absorption charging time:
12
±10%
Hours
Absorption charging transits to Equal charging conditions:
1) When charging current drops to: 0.5
±10%
Adc
Or 2) Maintain charge until the current acceptance drops by less than 0.10 amp over a 1 hour period
Max Equalizing Voltage:
30
±10%
Vdc
Max Equalizing Voltage:
1 ~ 8 (Subject to Bulk Charge time taken)
±10%
Adc