Batteryminder, Specific gravity – capacity – BatteryMINDer 28252-AA-Series User Manual
Page 10

Rev. I-100511
Page 10
P/N VDC28252-AA-Series-MNL
BatteryMINDer
®
Model 28252-AA-Series
TABLE 1
Temp. Compensated Hydrometer
- meter or 4 ball type
Full Capacity
Percentage
1.285
100%
1.245
75%
1.210
50%
1.175
25%
1.140
May denote shorted cell or battery
that has been severely discharged
and may not be recoverable
0%
Specific Gravity – Capacity
be thoroughly familiar with the safety and operating instructions.
4. Recharge the battery with the BatteryMINDer to ensure that
it is slowly and completely charged before you determine its
condition. Allow battery to “rest”* overnight or momentarily apply
a small load to remove the “surface” charge which creates false
voltage readings.
* “RESTED” = a battery that has been as fully charged as possible and left
disconnected from charger or any type load overnight. Apply a small load to
remove surface charge effect.