FOR FLOOR BOX AND LOW VOLTAGE DEVICE
PLATE INSTALLATION:
1.
Remove the brass cover from the floor box by pressing inward on
the three latches on the side of the box and pulling the cover
upwards.
2.
Push inward on the three latches (see Figure 7) that hold the
receptacle plate in place and remove the receptacle and plate
(see Figure 8).
3.
Install the appropriate low voltage wiring jacks (not included) into
the low voltage plate.
4.
Pull the low voltage cables up through the hole in the flooring (see
single receptacle instructions) and connect to the jacks.
5.
Align the three latches on the low voltage plate with the three latch
holes in the round floor box tube (see Figure 7). While aligning the
low voltage plate slots with the ribs on the inside of the round floor
box tube, push the low voltage plate back into the round floor box
tube until the three latches snap into the three latch holes in the
side of the tube. It may require extra force to push the low voltage
plate all the way down to the latch point. The low voltage plate is
made with a tough polycarbonate material and should not break
from push-in forces.
6.
Snap the round floor box tube back into the bottom of the brass
cover. Make sure that one of the slots on the brass cover rim lines
up with the rectangular plastic bump on the outer surface of the
round floor box tube (see Figure 9).
7.
Apply a bead of caulking to the top edge of the hole in the floor.
Drop the completed floor box assembly into the hole in the floor.
Using the two brass screws provided, screw the brass cover plate
down to the sub flooring.
8.
Remove the brass circular cover by prying open with a small
screwdriver. Plug in the low voltage cable(s) into the jack(s).