Page 48: Vfd indicator function description
48
Tran
Selects the transient mode. Press this key first to enable transient
mode before running A/B transient operation and then send the
triggering signal to run a program.
On/Off
Control module’s input on/off state
4. AIR INLET
Module’s air inlet for cooling purposes.
WARNING : Do not place any objects that may block or cover air inlet.
Module Panel Lock
Press Shift +
key to lock current channel’s keys and knob operation. To unlock, press Shift +
key again.
Switching Channels
There are three ways to switch channels:
1) Press Chan + number key
2) Press Chan + key
3) Press the number key of the channel in SETUP menu
Channel Synchronization
If you want to change the synchronization of the channels, you can set this in the Configuration
menu. Switch to the channel on the mainframe and then press Shift + ⑧ key to enter the
Configuration menu. Select and enter the
press Enter. When you turn on this function, the On/Off key can control the input state of the
corresponding module synchronously. In the same method, you can set up synchronization with
other channels. When in remote control mode, you can send SCPI command INPut:ALL ON to