Specifications

FREQUENCY
Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 to 1000 MHz

Accuracy . . . . . . . . . . ±10 ppm at 25°C; ±10 ppm drift over temp.;

±3 ppm/year aging

Resolution Bandwidths . . . . . . . . . . . . . . . 30, 280 kHz and 2 MHz

(30 kHz for CTB/CSO only)

Tuning Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 kHz

Sweep Resolution . . . . . . . . . . . . . . . . . . . . . . . 250 kHz maximum

LEVEL MEASUREMENT

Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40 to +60 dBmV

Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1 dB

Accuracy. . . . . . . . . . . . . . . . . . . . . . ±1.0 dB from -20 to +50°C1,2

Log Linearity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.5 dB1

Flatness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.5 dB3

Signal Types . . . . . . . . . . . . . . . . . . . . . . . CW, single carrier, video

(single or dual audio/NICAM), audio, digital

Uncertainty for Digital Carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . .

additional ±0.5 dB (digital types 16/32/64/256 QAM,

QPR, QPSK, VSB, CAP-16, DVB/ACTS and TDMA

using zero span spectrum mode) @280 kHz RBW

CARRIER-TO-NOISE

4

In-service measurement. Non-scrambled channels only. No prese-
lection required for 78 channels or less. Best dynamic range at +10
dBmV or higher input.

Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

52 dB1

Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 0.5 dB

HUM MEASUREMENT

In-service measurement. Carrier > 0 dBmV. Non-scrambled
channels only

Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 10%

Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <0.2%

Accuracy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.7%

DEPTH OF MODULATION

Assumes presence of white reference on any VITS line. Non-scram-
bled channels only. Audio demodulation of AM and FM carriers

Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 to 100%

Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <0.5% at 85%

Audio Demodulation . . . . . . . . . . . . . . . . . . AM and FM Carriers

TILT MEASUREMENT

Up to 9 pilot carriers or video channels with tilt and level measure-
ments on the highest and lowest.

Hi-Lo

Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1 dB

SCAN MODE

All video, audio, pilot carrier, and digital channel levels displayed.

SWEEP MODE

SDA-5000 and 5500 only

Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 to 1000 MHz

Display Span. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . user definable

Display Scale/Range. . 6 vertical divisions 1, 2, 5, or 10 dB/division

Sweep Pulse Occupied Bandwidth . . . . . . . . . . . . . . . . . . . . 30 kHz

Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.5 dB, normalized

(dependent on stability of referenced carriers)

Sweep Rate . . . . . . . . . . . . . . . . ~1 second (78 channels, including

scrambled and digital signal types)

Channel Plan Templates (user editable) . . . . . . . . . . . . . . . . . . . . .

China-1; China-2; France; HDTP-NL; Ireland;

Japan; Jerold; Jerold-HRC; Jerold-IRC; NCTA;

NCTA-HRC; NCTA-SUB; NCTA-IRC;

NTSC-Broadcast; OIRT-D/K; PL-B/G; PAL-UK

SPECTRUM MODE
Spans. . . . 3, 5, 10, 20, and 50 MHz (0.3, 0.5, 1, 2, and 5 MHz/div.)

Sweep Rates. . . . . . . . . . . ~1 second updates with spans of 50, 20,

10 and 5 MHz ~1.7 second updates with 3 MHz span

Display Scaling and Range . . . . . . . . . . . 0.5, 1, 2, 5, and 10 dB/div.

6 vertical divisions

Dwell. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . programmable 0-25 ms

Spurious Free Dynamic Range . . . . . . . . . . . . . . . . . . . . . . . 60 dB3

Sensitivity Without Preamp . . . . . . . . . . -40 dBmV 5 to 550 MHz

-35 dBmV 550 to 1000 MHz

Sensitivity With Preamp . . . . . . . . . . . . . -50 dBmV 5 to 550 MHz

-45 dBmV 550 to 1000 MHz

Max. Level With Preamp . . . . . . . . . . . . . . . . . . . . . . . +50 dBmV

ZERO-SPAN MODE
Video BW . . . . . . . . . . . . . . . . >1 MHz, 100 kHz, 10 kHz, 100 Hz

Resolution BW . . . . . . . . . . . . . . . . . . . . 2 MHz, 280 kHz, 30 kHz

Measurement BW Compensation programmable 1 kHz to 99 MHz

Pulse Measurement Accuracy . . . . . . . . . . . nominal level in 10 µs

±2 dB from nominal in 5 µs

(>1 MHz VBW, 280 kHz RBW)

Sweep Times . . . . . . . . . . . . . . . . . . . 100 µs to 20 s (1,2,5 settings)

INTERMODULATION DISTORTION (CSO/CTB)

Range5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

60 dB

Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1 dB

FORWARD TRANSMITTER

SDA-5000 with OPT 2/SDA-5500 only

Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 to 1000 MHz

Output Level . . . . . . . . . . . . . . . . . . . +20 to +50 dBmV adjustable

in 2 dB increments

Spectral Purity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hars -30 dBc

Spurs-35 dBc