MCL488 100-30-175
OPERATING MODES
Constant Current: 0 to 30A
Prog. Accuracy:
±0.25%
Regulation:
30mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode:
0 - 30 A/V
Low Res. Mode:
Infinite - 0.0333Ω
Low A/V Mode:
0 - 3 A/V
High Res. Mode:
Infinite - 0.333Ω
Prog. Accuracy:
±3% of Full Scale
Regulation:
±3% of Full Scale
Constant Voltage: 0 - 100V
Prog. Accuracy:
±0.50%
Regulation:
±0.15V
Constant Power:
0 to 175 Watts
Prog. Accuracy:
5 Watts
Regulation:
5 Watts
Short Circuit:
0.06Ω Max.
INPUT CHARACTERISTICS:
M
ODULE
S
PECIFICATIONS
0.1
1
100
10
1000
0.1
1
10
100
1000
AMPERES
VO
LT
S
0.1
1
100
10
1000
0.1
1
10
100
1000
AMPERES
VO
LT
S
MCL488 600-20-350
OPERATING MODES
Constant Current: 0 to 20A
Prog. Accuracy:
±0.25%
Regulation:
20mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode:
0 - 3 A/V
Low Res. Mode:
Infinite - 0.333Ω
Low A/V Mode:
0 - 0.333 A/V
High Res. Mode:
Infinite - 3Ω
Prog. Accuracy:
±3% of Full Scale
Regulation:
±3% of Full Scale
Constant Voltage: 0 - 600V
Prog. Accuracy:
±0.5%
Regulation:
±0.9V
Constant Power:
0 to 350 Watts
Prog. Accuracy:
10 Watts
Regulation:
10 Watts
Short Circuit:
0.33Ω Max.
INPUT CHARACTERISTICS:
MCL488 400-60-350
OPERATING MODES
Constant Current: 0 to 60A
Prog. Accuracy:
±0.25%
Regulation:
60mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode:
0 - 15 A/V
Low Res. Mode:
Infinite - 0.0667Ω
Low A/V Mode:
0 - 1.5 A/V
High Res. Mode:
Infinite - 0.667Ω
Prog. Accuracy:
±3% of Full Scale
Regulation:
±3% of Full Scale
Constant Voltage: 0 - 400V
Prog. Accuracy:
±0.25%
Regulation:
±0.6V
Constant Power:
0 to 350 Watts
Prog. Accuracy:
10 Watts
Regulation:
10 Watts
Short Circuit:
0.08Ω Max.
INPUT CHARACTERISTICS:
0.1
1
100
10
1000
0.1
1
10
100
1000
AMPERES
VO
LT
S