Eries, Pecifications c – Atec TDI-Power-MCL488 User Manual
Page 3
I
NNOVATIVE
T
EST
S
YSTEMS
... G
LOBAL
T
EST
S
OLUTIONS
ANALOG MODE
Ext. Prog:
0 to 10 Volts input yields 0 to full scale loading in
all operating modes.
Input Impedance: 330K Ohms
Prog. Response: Limited by internal adjustable slew rate limiter
Pulse Mode:
Two level or three level pulsing
available in any mode.
Min Pulse
Duration(Any level): 10mSec
Max Pulse
Duration(Any level): 16 Sec or 71 Min. with
reduced resolution and minimum duration
Resolution:
1mSec
Adjustable Slew Rate:
Max:
0 to full scale in 10µS
Min:
0 to full scale in 10mS
OUTPUT SIGNALS
Current Sample Output:
Scaling:
10 Volts = full scale Current
Accuracy:
±0.5% of full scale
PROTECTION
Current Limit:
105% of full scale current
Power Limit:
Approximately 370 Watts
Overvoltage:
Load disconnect at approximately 105% of full
scale voltage
Thermal:
Load disconnect at internal temperature of 105°C
Undervoltage:
Load inhibited at less than1 Volt, when enabled
METERS
Voltmeter Accuracy:±0.25%, ±1 Digit
Ammeter Accuracy: ±0.25%, ±1 Digit
Wattmeter Accuracy:
±0.5%, ±2 Digits
IEEE-488 READBACKS
Current:
Resolution:
1/4000 of Full Scale
Accuracy:
±0.5% ±1 Digit
Voltage:
Resolution:
1/4000 of Selected Full Scale
Accuracy:
±0.5% ±1Digit
Power:
Resolution:
87.5 mW
Accuracy:
±0.5% ±1Digit
MECHANICAL
Module Size:
1.58”W x 10.5”H x 24”D
40mm W x 267mm H x 610mm D
Module Weight: 12 lbs. / 5.44kg
Chassis Size:
19”W x 10.5”H x 24”D
483mm W x 267mm H x 610mm D
Rack Mountable
Full Chassis Weight: 125 lbs. / 56.70kg
MISCELLANEOUS
AC Input:
User Selectable
110VAC/220VAC,±10%, 48 - 62Hz @ 350W
Ambient Temp:
0°C to 40°C
S
ERIES
S
PECIFICATIONS
C
HASSIS
O
UTLINE