MCL488 50-100-350
MCL488 100-60-350
OPERATING MODES
Constant Current: 0 to 100A
Prog. Accuracy:
±0.50%
Regulation:
100mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode:
0 - 200 A/V
Low Res. Mode:
Infinite - 0.005Ω
Low A/V Mode:
0 - 20 A/V
High Res. Mode:
Infinite - 0.05Ω
Prog. Accuracy:
±3% of Full Scale
Regulation:
±3% of Full Scale
Constant Voltage: 0 - 50V
Prog. Accuracy:
±0.50%
Regulation:
±0.075V
Constant Power:
0 to 350 Watts
Prog. Accuracy:
10 Watts
Regulation:
10 Watts
Short Circuit:
0.004Ω Max.
INPUT CHARACTERISTICS:
OPERATING MODES
Constant Current: 0 to 60A
Prog. Accuracy:
±0.25%
Regulation:
60mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode:
0 - 60 A/V
Low Res. Mode:
Infinite - 0.0167Ω
Low A/V Mode:
0 - 6 A/V
High Res. Mode:
Infinite - 0.167Ω
Prog. Accuracy:
±3% of Full Scale
Regulation:
±3% of Full Scale
Constant Voltage: 0 - 100V
Prog. Accuracy:
±0.5%
Regulation:
±0.15V
Constant Power:
0 to 350 Watts
Prog. Accuracy:
10 Watts
Regulation:
10 Watts
Short Circuit:
0.016Ω Max.
INPUT CHARACTERISTICS:
M
ODULE
S
PECIFICATIONS
0.1
1
100
10
1000
0.1
1
10
100
1000
AMPERES
VO
LT
S
0.1
1
100
10
1000
0.1
1
10
100
1000
AMPERES
VO
LT
S
MCL488 100-15-350
OPERATING MODES
Constant Current: 0 to 15A
Prog. Accuracy:
±0.25%
Regulation:
2mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode:
0 - 15 A/V
Low Res. Mode:
Infinite - 0.666Ω
Low A/V Mode:
0 - 1.5 A/V
High Res. Mode:
Infinite - 6.66Ω
Prog. Accuracy:
±3% of Full Scale
Regulation:
±3% of Full Scale
Constant Voltage: 0 - 100V
Prog. Accuracy:
±0.5%
Regulation:
±0.15V
Constant Power:
0 to 350 Watts
Prog. Accuracy:
10 Watts
Regulation:
10 Watts
Short Circuit:
0.016Ω Max.
INPUT CHARACTERISTICS:
0.1
1
100
10
1000
0.1
1
10
100
1000
AMPERES
VO
LT
S