Sg series, 4–150 kw – Atec Sorensen-SG Series User Manual
Page 5

858.458.0223
SG Series
SGI / SGA Comparison Chart
Feature
SGA
SGI
Modular Design
•
•
Fast Load Transient
•
•
Parallelable
•
•
Analog & Digital Summing
Optional
•
Direct Front Panel V/I Control
•
•
3½ Digit LED Readout
•
Graphics Display
•
Sequencing
•
Save/Recall Setups
•
System Power Readouts
•
Constant Power Mode
•
IEEE-488.2/RS-232C
Optional
RS-232C Std, IEEE-488.2 Optional
LXI Class C Ethernet/ RS-232
Optional
RS-232C Std, Ethernet Optional
Front Panel Dust Filter
Optional (3U unit only)
Optional (3U unit only)
Advanced Power Simulation
SGI model provides constant power mode allowing independent setting of the max voltage, current and power
4–150 kW
Environmental
Operating Temperature
0 to 50º C
Storage Temperature
-25º C to 65º C
Humidity Range
Relative humidity up to 95% non-condensing, 0º C – 50º C
Altitude
Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating
to 40,000 ft. (~12,000 m)
Cooling
Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing.
Regulatory
Certified to UL/CSA 61010 and IEC/EN 61010-1 by a NRTL, CE Compliant, Semi-F47 Compliant.
LVD Categories: Installation Category II: Pollution Degree 2; Class II Equipment: for Indoor Use Only, back panel not user accessible
(see user manual for installation instructions)
EMC Directive, EN 61326:1998
Front Panel Dust Filter
30 PPI (Pores Per Inch) - must ensure adequate airflow and / or derate max. temperature. 3U unit only.