Display function, Save and print function, File operation – Atec Yokogawa-cw240 User Manual
Page 5: Communication function, Pc card interface
5
All Rights Reserved. Copyright © 2004, Yokogawa M&C Corporation
Display function
Display : 5.7 inches STN monochrome LCD (320 x 240 pixels) with backlight
Backlight
: Auto off, ON/OFF
Contrast
: Automatic compensation and 8 level setting by ambient temperature
Display digits
: Except electric power: 4 digits
Electric energy: 6 digits
Languages
: English/French/German/Italian/Spanish/Korean/Japanese
French,German,Italian,Spanish and Korean languages will be added soon.
Averaging function : Moving average method/ select from 2/5/10/20 times
Display hold function
: Hold/Release
Save and Print function
Manually or Automatically save/print
Memory
: Internal memory: 1MB or PC card
Print : Dedicated printer (RS-232 )
Save and print data : All measurement item, /Set value/Screen
Save and print interval : Standard interval:
1/2/5/10/15/30sec. /1/2/5/10/15/30/60min.
Less than 30 second interval, it impossible to output/print for harmonics measurement and waveform data.
Short time interval:
0.1/0.2/0.5second for each waveform
Data output item is only instantaneous value
Possible for data saving time display : Compute from free area of storage, data saved item and interval time
File operation
File copy
: File copy from internal memory to PC card
Read set file/ Save : Internal memory/ Reading of set file in the PC card/ Save
Deletion of file
: Delete internal set file/ Delete file in PC card
Format : PC card/ Initialize internal memory
File saving format : Measurement data: CSV format (Binary format when set to short time interval
Waveform data : Binary format
Display data : BMP format
Setting data : text format
Voltage dip/Swell/Data for instantaneous power failure : Text format
Communication function
Electric specification
: EIA RS-232
Synchronism method
: Start-Stop synchronism method
Baud rate
: 1200/2400/9600/19200/38400 bps
Connector
: D-SUB 9 pin
PC card interface
Slot
: Conforms with PC Card Standard TYPE Ⅱ×1
PC card
: Flush ATA card
Data format
: MS-DOS format
Recording contents : Setting data/Measurement data/Display data