Characteristics – Atec Tektronix-MSO4000 Series User Manual
Page 11
Mixed Signal Oscilloscopes — MSO4000 Series, DPO4000 Series
Characteristics
Vertical System Analog Channels
Characteristic
DPO4034
MSO4034
DPO4054
MSO4054
DPO4104
MSO4104
Input Channels
4
4
4
Analog Bandwidth (–3 dB) 5 mV/div -
1 V/div
350 MHz
500 MHz
1 GHz
Calculated Rise Time 5 mV/div (typical)
1 ns
700 ps
350 ps
Hardware Bandwidth Limits
20 MHz or 250 MHz
Input Coupling
AC, DC, GND
Input Impedance
1 MΩ ±1%, 50 Ω ±1%
Input Sensitivity, 1 MΩ
1 mV/div to 10 V/div
Input Sensitivity, 50 Ω
1 mV/div to 1 V/div
Vertical Resolution
8 bits (11 bits with Hi Res)
Max Input Voltage, 1 MΩ
250 V
RMS
with peaks ≤ ±400 V
Max Input Voltage, 50 Ω
5 V
RMS
with peaks < ±20 V
DC Gain Accuracy
±1.5% with offset set to 0 V
Channel-to-Channel Isolation
≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth for any two channels having equal volts/div settings
Offset Range
Range
1 MΩ
50 Ω, 75 Ω
1 mV/div to 50 mV/div
±1 V
±1 V
50.5 mV/div to
99.5 mV/div
±0.5 V
±0.5 V
100 mV/div to 500 mV/div
±10 V
±10 V
505 mV/div to 995 mV/div
±5 V
±5 V
1 V/div to 5 V/div
±100 V
±5 V
5.05 V/div to 10 V/div
±50 V
NA
Vertical System Digital Channels
Characteristic
All MSO4000 Models
Input Channels
16 Digital (D15 - D0)
Thresholds
Per-channel Thresholds
Threshold Selections
TTL, CMOS, ECL, PECL, User Defined
User-defined Threshold
Range
+5 to –2 V
Maximum Input Voltage
±15 V
Threshold Accuracy
±(100 mV + 3% of threshold setting)
Input Dynamic Range
6 V
p-p
centered around the threshold
Minimum Voltage Swing
500 mV
Input Impedance
20 kΩ
Probe Loading
3 pF
Vertical Resolution
1 bit
Horizontal System Analog Channels
Characteristic
DPO4034
MSO4034
DPO4054
MSO4054
DPO4104
MSO4104
Maximum Sample
Rate (All channels)
2.5 GS/s
2.5 GS/s
5 GS/s
Maximum
Record Length
(All channels)
10M points
Maximum Duration
at Highest Sample
Rate (All channels)
4 ms
4 ms
2 ms
Time Base Range
1 ns to 1,000 s
400 ps to 1,000 s
Time Base Delay
Time Range
–10 divisions to 5000 s
Channel-to-Channel
Deskew Range
±100 ns
Time Base
Accuracy
±5 ppm over any ≥1 ms interval
Horizontal System Digital Channels
Characteristic
All MSO4000 Models
Maximum Sample Rate
(Main)
500 MS/s (2 ns resolution)
Maximum Record Length
(Main)
10M points
Maximum Sample Rate
(MagniVu)
16.5 GS/s (60.6 ps resolution)
Maximum Record Length
(MagniVu)
10k points centered around the trigger
Minimum Detectable
Pulse Width
1.5 ns
Channel-to-Channel
Skew
500 ps typical
www.tektronix.com
11