Features common to Thermo Scientific NESLAB ThermoFlex recirculating chillers
Options include:
Feature
Benefit
Pressure Relief
The pressure relief valve allows the user to set the maximum fluid pressure to meet the application requirements
and is available as an internal or external option.
Pressure Relief with Flow Readout
The pressure relief valve allows the user to set the maximum fluid pressure to meet the application requirements.
The flow readout allows the user to monitor the flow rate to the application and set flow alarms via the controller.
Flow Control with Flow Readout
The flow control valve allows the user to adjust the flow to the application.
The flow readout allows the user to monitor the flow rate to the application and set flow alarms via the controller.
Auto Refill
Allows for automatic refilling from a customer-supplied water source to ensure the proper fluid level is maintained.
Anti Drainback
Prevents fluid from flowing back to the reservoir when the chiller is installed below the application.
DI Water
Partial flow internal DI cartridge minimizes footprint and provides fluid resistivity between 1 and 3 megOhm.
RS232 & RS485 Digital Communication Provides digital communication for remote operation, monitoring and data logging.
Analog I/O
Provides analog communication for remote operation and monitoring. Includes a remote sensor port which allows for
remote temperature control of an application when used with a remote sensor (available as an accessory).
Global Voltage
Allows the user to select the appropriate frequency and voltage to enable operation anywhere in the world.
Air-Cooled Condenser
Uses ambient-temperature room air to remove application heat.
Water-Cooled Condenser
Uses facility water to remove application heat.
SEMI S2 Compliance
Compliant with S2-0703, S8-0705, S14-0704, F47-0706.
Deluxe Controller
LCD controller offers the ultimate in ease of use with graphical display and text.
Multi-position level sensor enables user to easily monitor the fluid level on the display.
DI Control and Readout*
Allows the user to both set and readout the DI level between 1 and 3 megOhm using the controller.
High Temperature*
Allows for operation from +5°C to +90°C.
*Available with the deluxe controller option.
Standard Controller
• Single line
LED Display
• Temperature alarms
• Pressure alarms
• Flow alarms (optional)
Deluxe Controller
• Multi-line LCD Display
• Full alphanumeric
display
• Temperature alarms
• Pressure alarms
• Fluid level readout
• Flow alarms (optional)
• DI control & readout
(optional)