beautypg.com

The smart 4 kv solution for ce applications, Nsg 3040 – Atec Teseq-Schaffner-NSG3040 User Manual

Page 4

background image

A d v a n c e d Te s t S o l u t i o n s f o r E M C

THE SMART 4 KV SOLUTION FOR CE APPLICATIONS

NSG 3040

Internal coupling network

Parameter

Value

Decoupling attenuation:

Remanent pulse 15% max.

Mains side crosstalk 15% max.

Mains decoupling:

1.5 mH 0% + 35%

Connections:

Back panel:

EUT supply: Harting connector

Additional ground connector

Instrument supply 230/115 VAC

Front panel:

EUT connector IEC 320

HV coaxial

Connector surge high & low

EUT supply:

1-phase

EUT VAC:

24 to 260 Vrms, 50/60 Hz (phase - neutral), 400 Hz max.

EUT VDC:

0 to 260 VDC

EUT current

1 x 16 Arms continuous (temperature controlled)

1 x 25 Arms for 15 min

EFT (Burst)

Standard coupling all lines to ref ground (GND)

IEC/EN 61000-4-4

L, N, PE

ref GND

Any lines and combinations to ref GND:

L

ref GND

N

ref GND

PE

ref GND

L, N

ref GND

L, PE

ref GND

N, PE

ref GND

PQT:

Dips & drops to phase L

Field:

1 to max. 40 A/m (in 1 A/m steps)

Frequency:

50/60 Hz

Coil factor:

0.01 to 99.99

Test duration:

1 to 9’999 pulses, continuous

Power magnetic field in conjunction with MFO 6501 / MFO 6502 and INA 70x
conforms to IEC/EN 61000-4-8