Parameter
Value
Pulse amplitude:
±200 V to 4.8 kV (in 1 V steps) - open circuit
±100 V to 2.4 kV (50 Ω matching system)
Burst frequency:
100 Hz to 1000 kHz
Polarity:
positive / negative / alternate
Repetition time:
1 ms to 4200 s (70 min)
Burst time:
1 µs to 1999 s, single pulse, continuous
Test duration:
1 s to 1000 h
Phase synchonization:
asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling:
ANSI / IEC / external
Burst (EFT) 5/50 ns
Pulse conforms to IEC/EN 61000-4-4
Dips & drops
conforms to IEC/EN 61000-4-11
Parameter
Value
Dips & drops:
From EUT voltage input to 0 V, 0%
Uvar with optional variac:
depending on model (VAR 650x)
Uvar with step transformer:
0, 40, 70, 80% (INA 650x)
Peak inrush current capability:
500 A (at 230 V)
Switching times:
1 to 5 μs (100 Ω load)
Event time:
20 µs to 1999 s, 1 to 99’999 cycles
Test duration:
1 s to 70’000 min, 1 to 99’999 events, continuous
Repetition time:
40 µs to 35 min, 1 to 99’999 cycles
Phase synchronization:
asynchronous, synchronous 0 to 359º (in 1º steps)
Variation test
conforms to IEC/EN 61000-4-11
Parameter
Value
Uvar with optional variac:
0 to 265 V (in 1 V steps), 0 to 115% (in 1% steps)
Repetition time:
1 ms to 35 min, 1 to 99’999 cycles
Test duration:
1 ms to 5 s, 1 to 250 cycles (50 Hz);
1 to 300 cycles (60 Hz), abrupt
Repetition time:
10 ms to 10 s; 1 to 250 cycles (50 Hz), 1 to 300 cycles (60 Hz)
Test duration:
1 s to 99’999 min, 1 to 99’999 events, continuous
Phase synchronization:
asynchronous, synchronous 0 to 359º (in 1º steps)