475 field communicator, Universal – hart and f, Fieldbus – Atec Rosemount-Hart-475 User Manual
Page 3: With over 1,100 different hart and f, Page 3, Oundation
Through Easy Upgrade, you
always have access to the latest
HART and fieldbus drivers. With
the 475 Field Communicator, you
are guaranteed universal HART
and F
OUNDATION
fieldbus support
in a single, intrinsically safe
handheld communicator.
Page 3
Online Licensing
The Online Licensing capability
provided with Easy Upgrade
allows you to enable new options
for your 475 Field Communicator
over the Internet. With Online
Licensing, powerful options like
F
OUNDATION
fieldbus can be added
by simply purchasing the license
and downloading it directly to
your communicator.
Universal – HART and
F
OUNDATION
fieldbus
With over 1,100 different HART
and F
OUNDATION
fieldbus devices
available from more than 100
manufacturers, the 475 Field
Communicator works with all
your devices to positively
impact your bottom line.
475 Field Communicator
The Easy Upgrade Utility allows you to transfer system software, DDs, and HART device configurations between the
475 Field Communicator and a PC. Connect using IrDA, Bluetooth, or an SD Card Reader.
(
(
()
)
)
Tag: PT-105
Manufacturer: Rosemount
Model: 3051S Diag
146 Variables
Printed on: 5/19/2009 9:06:38 AM
Device Configuration
Parameter
Variation Custom S...
2nd Variable
3rd Variable
Abnormal Situation P...
Alarm Direction
Analog Output
Baseline Mean Value...
Baseline Standard D...
Burst Mode
Burst Option
Calibration Type
Cutoff Mode
Damping
Damping
Date
Descriptor
Dev flags
Device Status
Diaphragm Material
Distributor
Drain Vent Matl
Electronics HW Rev
Electronics S/N
Electronics SW Rev
Fact trm recal loc
Field Device Rev
100%
Sensor Temperature
Scaled Variable
0x00
Hi
3,999 mA
0.000000 inH20
0.000000 inH20
Off
Unknown Enumerato...
Diff (DP)
Off
0.90 s
0.00 s
02/14/2008
PRODUCTION XMT...
0x00
0x50
None
Rosemount
316 SST
1
407
5
Sensor trim
1
Value
Parameter
Lower Sensor Limit
Lower Trim Point
Manufacturer
Maximum Temperat...
Mean
Mean Change Check
Mean Change Sensit...
Mean Chg Action
Mean Custom Sens...
Mean Lower Thresh...
Mean Upper Thresh...
Measurement
Message
Min Span
Min Span
Min Span
Mode
Model
Model Number I
Model Number II
Model Number III
Module Config
Module Range
No Label Available
Num req preams
Number
0.00000
0.0
Rosemount
80.002 F
-0.031420 inH20
6*
Medium
Alert
100%
0.000000 inH20
0.000000 inH20
Diff (DP)
MISSING CAP
4.5
0.00000
0.0
Off
3051S Diag
1
2
3
Std coplanar (C)
3
0x00
5
None
Value
Easily store and print device configurations for analysis and documentation