beautypg.com

475 field communicator, Universal – hart and f, Fieldbus – Atec Rosemount-Hart-475 User Manual

Page 3: With over 1,100 different hart and f, Page 3, Oundation

background image

Through Easy Upgrade, you

always have access to the latest

HART and fieldbus drivers. With

the 475 Field Communicator, you

are guaranteed universal HART

and F

OUNDATION

fieldbus support

in a single, intrinsically safe

handheld communicator.

Page 3

Online Licensing

The Online Licensing capability

provided with Easy Upgrade

allows you to enable new options

for your 475 Field Communicator

over the Internet. With Online

Licensing, powerful options like

F

OUNDATION

fieldbus can be added

by simply purchasing the license

and downloading it directly to

your communicator.

Universal – HART and

F

OUNDATION

fieldbus

With over 1,100 different HART

and F

OUNDATION

fieldbus devices

available from more than 100

manufacturers, the 475 Field

Communicator works with all

your devices to positively

impact your bottom line.

475 Field Communicator

The Easy Upgrade Utility allows you to transfer system software, DDs, and HART device configurations between the

475 Field Communicator and a PC. Connect using IrDA, Bluetooth, or an SD Card Reader.

(

(

()

)

)

Tag: PT-105

Manufacturer: Rosemount

Model: 3051S Diag

146 Variables

Printed on: 5/19/2009 9:06:38 AM

Device Configuration

Parameter

Variation Custom S...

2nd Variable

3rd Variable

Abnormal Situation P...

Alarm Direction

Analog Output

Baseline Mean Value...

Baseline Standard D...

Burst Mode

Burst Option

Calibration Type

Cutoff Mode

Damping

Damping

Date

Descriptor

Dev flags

Device Status

Diaphragm Material

Distributor

Drain Vent Matl

Electronics HW Rev

Electronics S/N

Electronics SW Rev

Fact trm recal loc

Field Device Rev

100%

Sensor Temperature

Scaled Variable

0x00

Hi

3,999 mA

0.000000 inH20

0.000000 inH20

Off

Unknown Enumerato...

Diff (DP)

Off

0.90 s

0.00 s

02/14/2008

PRODUCTION XMT...

0x00

0x50

None

Rosemount

316 SST

1

407

5

Sensor trim

1

Value

Parameter

Lower Sensor Limit

Lower Trim Point

Manufacturer

Maximum Temperat...

Mean

Mean Change Check

Mean Change Sensit...

Mean Chg Action

Mean Custom Sens...

Mean Lower Thresh...

Mean Upper Thresh...

Measurement

Message

Min Span

Min Span

Min Span

Mode

Model

Model Number I

Model Number II

Model Number III

Module Config

Module Range

No Label Available

Num req preams

Number

0.00000

0.0

Rosemount

80.002 F

-0.031420 inH20

6*

Medium

Alert

100%

0.000000 inH20

0.000000 inH20

Diff (DP)

MISSING CAP

4.5

0.00000

0.0

Off

3051S Diag

1

2

3

Std coplanar (C)

3

0x00

5

None

Value

Easily store and print device configurations for analysis and documentation