beautypg.com

Atec JDSU-DSM-6300 User Manual

Page 11

background image

11

DSAM-6300 DigitAl Service AnAlySiS Meter

Specifications

Analog-Level Measurement

Signal types CW, video, and audio (NTSC, PAL, and SECAM)
Frequency range

4 to 1,000 MHz

Accuracy ±10 ppm at 25°C (77°F) 10 kHz tuning resolution
Measurement range

1 –40 to +60 dBmV (typical)

Resolution

0.1 dB

Resolution bandwidth

280 kHz

Accuracy

3

±1.5 dB typical at 25°C (77°F)

Carrier-to-Noise

30 to 45 dB ±2 dB
45 to 48 dB ±3 dB
Input at >0 dBmV (up to 750 MHz)
Input at >6 dBmV (750–1,000 MHz)

Hum

Accuracy up to 5% hum

±0.8%

From 5 to 10%

±1.0%

Digital-Level Measurement

Modulation types

QPSK, QAM (DVB/ACTS)

Range

2

–40 to +50 dBmV (typical)

Resolution

0.1 dB

Accuracy

3

±2.0 dB typical at 25°C (77°F)

Downstream QAM Demodulation

Modulation type 64, 128, and 256 QAM, ITU-T J.83 (Annex A,
B, or C selectable at time of order, factory installed hardware)
Input range (lock range)

4

–15 to +50 dBmV total integrated

power from:
57–1,000 MHz (42 MHz diplexer 6 MHz channel spacing)
83–1,000 MHz (65 MHz diplexer 6 MHz channel spacing)
108–1,000 MHz (85 MHz diplexer 6 MHz channel spacing)
58–1,000 MHz (42 MHz diplexer 8 MHz channel spacing)
84–1,000 MHz (65 MHz diplexer 8 MHz channel spacing)
109–1,000 MHz (85 MHz diplexer 8 MHz channel spacing)
50 kHz tuning resolution
BER

5

pre and post FEC

10

-4

to 10

-9

MER

2

Range 64 QAM

21 to 45 dB

4

Accuracy

± 2 dB (up to 40 dB typical)

2

Range 128 QAM

25 to 45 dB

4

Accuracy

±2 dB (up to 40 dB typical)

2

Range 256 QAM

28 to 45 dB

4

Accuracy

± 2 dB (up to 40 dB typical)

2

Symbol rate
Annex A

5.057 to 6.952 MSPS for 64, 128, and 256 QAM

Annex B 5.057 MSPS for 64 QAM and 5.361 MSPS for 256 QAM
Annex C 5.274 MSPS for 64 QAM, and 5.361 MSPS for 256 QAM

DOCSIS testing

Support for operating in DOCSIS 1.0, 1.1, 2.0, or 3.0 modes
Compliant with CableLabs® specifications for DOCSIS 1.0, 1.1,
2.0, and 3.0
CableLabs-compliant BPI+ root-chained certificates pre-installed
EuroCableLabs® certificates available

Downstream Testing

Support for channel bonding of 8 downstream carriers
Throughput testing

up to 304 Mbps (6 MHz carriers)

and 400 Mbps (8 MHz carriers)

5

Upstream Testing

Support for channel bonding of 4 upstream carriers
Throughput testing

up to 120 Mbps

5

Upstream transmit range and diplexer crossover
(DOCSIS modes only)
5 to 42 MHz 42/88 MHz
(min. downstream DOCSIS center freq. 91 MHz)
5 to 65 MHz 65/96 MHz
(min. downstream DOCSIS center freq. 100 MHz)
5 to 85 MHz 85/111 MHz
(min. downstream DOCSIS center freq. 111 MHz)
Upstream modulation QPSK,

+52 dBmV with 64 QAM

16 QAM, 32 QAM, and

+55 dBmV with 16 QAM, and

64 QAM as instructed

+58 dBmV with QPSK

by CMTS transmitter
output at 25°C (77°F) maximum
(typical for a single transmit channel)

Upstream Spectrum, Ingress Scan

Spans

4 to 42 MHz, 4 to 65 MHz,

4 to 85 MHz, 4 to 110 MHz (option)

Sweep rate

<2 s

Display scaling and range

1, 2, 5, and 10 dB/division;

6 vertical divisions freq. 91 MHz)

Resolution bandwidth

280 kHz

Sensitivity

2

–45 to +60 dBmV (typical)

Downstream Spectrum, Forward Scan

(optional)

Frequency range

4 to 1000 MHz

Sweep rate

<2.5 s (display)

Display scaling and range

1, 2, 5 and 10 dB/division;

6 vertical divisions

Resolution bandwidth

30 or 280 kHz

Span

10 or 50 MHz

Sensitivity

–35 to 60 dBmV (typical)

Low-pass filter (matches diplexer frequency)
Reverse path sensitivity

–45 to +60 dBmV (typical)

(with low-pass filter on)

Sensitivity

2

–45 to +60 dBmV (typical)

Constellation (optional)

Modulation type

64, 128, and 256 QAM

Constellation points

2,000, 4,000, 8,000, 16,000,

32,000, or 64,000

Return QAM Generator

Signal modulations

16 QAM, 64 QAM

Symbol rates (MSPS)

1.28, 2.56, 5.12 modes only)

Frequency range

5–42 MHz, 5–65 MHz, 5–85 MHz

Supported levels

8.0–58.0 dBmV 2.0, and 3.0

Notes

1. Total integrated power, detectable range.

2. MER Typical defined as identical QAM carriers at +5 dBmV

with no adjacent analog carrier.

3. Accuracy for analog levels between –20 to +55 dBmV.

Accuracy for digital levels between –20 to +50 dBmV.

Additional uncertainty of ±1.0 dB from 4 to 15 MHz.

Additional uncertainty of ±0.5 dB across –20 to +50°C.

4. MER Range declines as input levels decrease. Expected MER

Range at MIN LOCK Level of –15 dBmV is >30 dB MER.

5. Stated throughput is the max theoretical capability. Actual

performance may vary.

DSAM Sweep Specifications (optional)

Forward sweep

Requires SDA-5500 (SDA-compatible mode)

Reverse sweep and reverse alignment

Requires SDA-5500 (single reverse) or
SDA-5510 (multiple reverse)
(SDA-compatible mode)

Sweep modes

Frequency range

5–1,000 MHz forward

5–65 MHz reverse

Display span

user-definable

Display scale/range 6 vertical divisions 1, 2, 5, or 10 dB/division
Sweep pulse-occupied bandwidth

30 kHz

Stability

±0.5 dB, normalized

(dependent upon stability of referenced carriers)
Sweep rate

~1 s

(78 channels, including scrambled and digital signal types)

Return Loopback/Sweep/Alignment

Frequency range

5–65 MHz

Transmit level

8–55 dBmV

Standards Compliance

Shock and vibration

5 Gs at 2 Hz to 5 kHz

Transportation packaging I.S.T.A.

Procedures 1C and 1G

Drop

IEC 61010

Handle stress

IEC 61010

Water resistance

MIL-STD-810F

Safety emissions

EN 55022, CE, FCC

Safety immunity

EN 61000, CE, FCC

General

Display

320 x 240 pixels, TFT color

Second language options

Chinese, French, German, Hungarian, Japanese, Korean,
Portuguese, Polish, or Spanish
Dimensions with battery (W x H x D)

12 x 25 x 10.8 cm

(without QAM HW option)

(4.75 x 9.75 x 4.25 in)

Dimensions with battery (W x H x D)

12 x 25 x 12.1 cm

(with QAM HW option)

(4.75 x 9.75 x 4.75 in)

Weight without battery

1.2 kg

(without QAM HW option)

(2 lb, 10 oz)

Weight without battery

1.4 kg

(with QAM HW option)

(3 lb, 0 oz)

Battery weight

0.6 kg

(1 lb, 6 oz)

Storage and operating temperature range

–20 to +50°C

(–4 to +122°F)