beautypg.com

Rf power meter (standard), Optical power meter (option 13) – Atec JDSU-JD746A User Manual

Page 3

background image

3

JD746A CELLADVISOR RF ANALYZER

Dynamic Range

Reflection

60 dB

Maximum Input Level

Average continuous power

+25 dBm (nominal)

DC voltage

±50 VDC

Interference immunity
On channel

On frequency


+17 dBm @>1.4 MHz from carrier frequency
(nominal)
0 dBm within ±10 kHz from the carrier fre-
quency (nominal)

Measurements

Reflection (VSWR)
VSWR range
Return loss range
Resolution


1 to 65
0 to 60 dB
0.01

Distance to Fault (DTF)
Vertical VSWR range
Vertical return loss range
Vertical resolution
Horizontal range

Horizontal resolution


1 to 65
1 to 60 dB
0.01
0 to (# of data points – 1) x Horizontal Resolution
Maximum = 1500 m (4921 ft)
(1.5x10

8

) x (V

P

) / (delta) x (0.95)

V

P

= propagation velocity

Delta = stop freq. – start freq. (Hz)

Cable Loss (1-port)
Range
Resolution


0 to 30 dB
0.01 dB

1-port Phase
Range
Resolution


–180° to +180°
0.01°

Smith Chart
Resolution


0.01

RF Power Meter (Standard)

General Parameters

Display range

–100 to +100 dBm

Offset range

0 to 60 dB

Resolution

0.01 dB or 0.1xW (x = m, u, p)

Internal RF Power Sensor

Frequency range

10 MHz to 4 GHz

Span

100 kHz to 100 MHz

Dynamic range

–120 to +20 dBm

Maximum power

+20 dBm

Accuracy

Same as spectrum analyzer

External RF Power Sensors

Directional Power Sensor

JD731B

Frequency range

300 MHz to 3.8 GHz

Dynamic range

0.15 to 150 W (average)
4 to 400 W (peak)

Connector type

Type-N female on both ends

Measurement type

Forward/reverse average power, forward peak
power, VSWR

Accuracy

±(4% of reading + 0.05 W)

1,2

Directional Power Sensor
Frequency range

JD733A
150 MHz to 3.5 GHz

Dynamic range

0.1 to 50 W (average)
0.1 to 50 W (peak)

Connector type

Type-N female on both ends

Measurement type

Forward/reverse average power, forward peak
power, VSWR

Accuracy

±(4% of reading + 0.05 W)

1,2

Terminating Power Sensor

JD732B

Frequency range

20 MHz to 3.8 GHz

Dynamic range

–30 to +20 dBm

Connector type

Type-N male

Measurement type

Average

Accuracy

±7%

1

Terminating Power Sensor

JD734B

Frequency range

20 MHz to 3.8 GHz

Dynamic range

–30 to +20 dBm

Connector type

Type-N male

Measurement type

Peak

Accuracy

±7%

1

Terminating Power Sensor

JD736B

Frequency range

20 MHz to 3.8 GHz

Dynamic range

–30 to +20 dBm

Connector type

Type-N male

Measurement type

Average and Peak

Accuracy

±7%

1

1. CW condition at 25°C ±10°C
2. Forward power

Optical Power Meter (Option 13)

Optical Power Meter

Display range

–100 to +100 dBm

Offset range

0 to 60 dB

Resolution