Specifi cations options, Dimensions – Atec Kikusui-PLZ6000R User Manual
Page 4
Printed in Japan
Issue:Jun.2011 201106PDFEC21
■ All products contained in this catalogue are equipment and devices that are premised on use under the supervision
of qualifi ed personnel, and are not designed or produced for home-use or use by general consumers.
■ Specifi cations,
design and so forth are subject to change without prior notice to improve the quality.
■ Product names and prices are
subject to change and production may be discontinued when necessary.
■ Product names, company names and
brand names contained in this catalogue represent the respective registered trade name or trade mark.
■ Colors,
textures and so forth of photographs shown in this catalogue may differ from actual products due to a limited fi delity in
printing.
■ Although every effort has been made to provide the information as accurate as possible for this catalogue,
certain details have unavoidably been omitted due to limitations in space.
■ If you fi nd any misprints or errors in this
catalogue, it would be appreciated if you would inform us.
■ Please contact our distributors to confi rm specifi cations,
price, accessories or anything that may be unclear when placing an order or concluding a purchasing agreement.
■Distributor:
530 Lakeside Drive, Suite#180, Sunnyvale, CA 94085, U.S.A.
Phone : 408-733-3432 Facsimile : 408-733-1814
www.kikusuiamerica.com
1-877-876-2807
www.kikusui.cn
Room, D-01,11F, Majesty Bld, No.138, Pudong Ave, Shanghai City
Phone : 021-5887-9067 Facsimile : 021-5887-9069
Specifi cations
Options
Rating
Operating voltage (DC)
30 V range
3 V to 30 V
60 V range
6 V to 60 V
Current
30 V range
400 A
60 V range
200 A
Power
6000 W
Constant Current (CC) mode
Operating range
30 V range
0 A to 400 A
60 V range
0 A to 200 A
Setting range
30 V range
0 A to 408 A
60 V range
0 A to 204 A
Resolution
10 mA
Setting accuracy
± (0.4% of set + 400 mA)
Input voltage variation
400 mA
Ripple
rms
500 mA
p-p
2 A
Constant Resistance (CR) mode
Operating range
30 V range
134 S to 2.5 mS
(7.4627 mΩ to 400 Ω)
60 V range
34S to 2.5 mS
(29.412 mΩ to 400 Ω)
Setting range
30 V range
136 S to 0 S
(7.3529 mΩ to OPEN)
60 V range
34 S to 0 S
(29.412 mΩ to OPEN)
Setting accuracy
± (0.5% of set* + 2 A) *set = Vin/Rset
Constant Voltage (CV) mode
Operating range
30 V range
3 V to 30 V
60 V range
6 V to 60 V
Setting range
30 V range
3 V to 30 V
60 V range
6 V to 60 V
Resolution
1 mV
Setting accuracy
± (0.1% of set + 60 mV)
Input current variation
12 mV
Constant Power (CP) mode
Operating range
0 W to 6000 W
Setting range
0 W to 6300 W
Resolution
0.1 W
Setting accuracy
± (1% of set + 60 W)
Voltmeter
Display
0.000 V to 60.000 V
Resolution
0.002 V
Accuracy
± (0.1% of reading + 60 mV)
Ammeter
Display
0.00 A to 400.00 A
Resolution
0.01 A
Accuracy
± (0.3% of reading + 300 mA)
Wattmeter
Display
0.0 W to 6000.0 W
Resolution
0.1 W
Protection function
DC side
Overvoltage protection (OVP), Overcurrent protection (OCP), Overpower protection (OPP),
Overheat protection (OHP), Reverse connection protection (REV), Undervoltage protection (UVP)
AC side
Voltage range error (outside the 170 V-240 V range)
Frequency range error (outside the 45 Hz-65 Hz range)
Open phase (when one of the three phases is missing)
Soft start
Operation mode
CC mode
Selectable time range
20 ms, 50ms, 100 ms, 200 ms
Time accuracy
± (30% of set + 100 μs)
Remote sensing
Compensation voltage
2 V for a single line (The sensing line is switched by a relay.)
Sequence function
Operation mode
CC, CR, CV, CP
Maximum number of steps
256
Step execution time
10 ms to 999 h 59 min
Resolution
10 ms to 1 min
Other functions
Elapsed time display
Measures the time from load on to load off.
Can be set in the range of 1 s to 999 h 59 min 59 s or off.
Auto load off timer
Automatically turns off the load after a specifi ed time elapses.
Can be set in the range of 1 s to 999 h 59 min 59 s or off.
Communication interface
GPIB, RS-232C, and USB interfaces are equipped as standard.
External controls
(J1 connector on the rear
panel)
External voltage (0 to 10 V): CC/CR/CP control
External voltage (0 to 10 V): CV control
External resistance (0 to 10 kΩ): CC/CR/CP control
External resistance (0 to 10 kΩ): CV control
LOAD ON.OFF
TTL level signal
Range selection
Mode selection
Preset memory A/B/C
Trigger input
Pause cancellation (TTL)
Monitor signal output
V MON (voltage)
5 V f.s (30 V range) /10 V f.s (60 V range)
I MON (current)
10 V f.s (30 V range) /5 V f.s (60 V range)
Status signal output
LOAD ON status
On when the load is on.
ALARM status
On when an alarm processing is in progress.
RANGE status
On when the 30 V range is selected.
Trigger signal output
TRIG OUT; BNC terminal on the front side (approx. 4.5 V, 1 ms wide)
General specifi cations
Input voltage range
AC180 V to 220 V (3-phase 3-wire)
Input frequency range
47 Hz to 63 Hz
Power consumption
200 VA (when no load is input)
Maximum regenerated power 5600 VA
Power regeneration effi ciency 85% or more
Dimensions
Width: 430 mm (16.93") / Height: 173 mm (6.81") / Depth: 550 mm (21.65")
Weight
Approx. 43 kg (94.8 lbs.)
Accessories
Manual, DC input terminal covers, etc.
Description
Model name
Specifi cation
Power cable
AC8-4P4M-M6C
3-phase, 4-core, 8mm
2
-wide M6 cable
Parallel operation cable
PC01-PLZ-4W
Flat cable about 300 mm long
Rack mounting bracket
KRB4
EIA (inch)
KRB200
JIS (millimeter)
173
430
MAX195
MAX665
MAX20
550
32.5
31
115
27
4-M4 screw holes including those on the opposite side (maximum depth: 12 mm)
303
50
50
4-M4 screw holes (maximum depth: 6 mm)
40
470
40
Dimensions
(mm)