beautypg.com

Specifi cations options, Dimensions – Atec Kikusui-PLZ6000R User Manual

Page 4

background image

Printed in Japan

Issue:Jun.2011 201106PDFEC21

■ All products contained in this catalogue are equipment and devices that are premised on use under the supervision
of qualifi ed personnel, and are not designed or produced for home-use or use by general consumers.

■ Specifi cations,

design and so forth are subject to change without prior notice to improve the quality.

■ Product names and prices are

subject to change and production may be discontinued when necessary.

■ Product names, company names and

brand names contained in this catalogue represent the respective registered trade name or trade mark.

■ Colors,

textures and so forth of photographs shown in this catalogue may differ from actual products due to a limited fi delity in
printing.

■ Although every effort has been made to provide the information as accurate as possible for this catalogue,

certain details have unavoidably been omitted due to limitations in space.

■ If you fi nd any misprints or errors in this

catalogue, it would be appreciated if you would inform us.

■ Please contact our distributors to confi rm specifi cations,

price, accessories or anything that may be unclear when placing an order or concluding a purchasing agreement.

■Distributor:

530 Lakeside Drive, Suite#180, Sunnyvale, CA 94085, U.S.A.
Phone : 408-733-3432 Facsimile : 408-733-1814

www.kikusuiamerica.com

1-877-876-2807

www.kikusui.cn

Room, D-01,11F, Majesty Bld, No.138, Pudong Ave, Shanghai City
Phone : 021-5887-9067 Facsimile : 021-5887-9069

Specifi cations

Options

Rating

Operating voltage (DC)

30 V range

3 V to 30 V

60 V range

6 V to 60 V

Current

30 V range

400 A

60 V range

200 A

Power

6000 W

Constant Current (CC) mode

Operating range

30 V range

0 A to 400 A

60 V range

0 A to 200 A

Setting range

30 V range

0 A to 408 A

60 V range

0 A to 204 A

Resolution

10 mA

Setting accuracy

± (0.4% of set + 400 mA)

Input voltage variation

400 mA

Ripple

rms

500 mA

p-p

2 A

Constant Resistance (CR) mode

Operating range

30 V range

134 S to 2.5 mS
(7.4627 mΩ to 400 Ω)

60 V range

34S to 2.5 mS
(29.412 mΩ to 400 Ω)

Setting range

30 V range

136 S to 0 S
(7.3529 mΩ to OPEN)

60 V range

34 S to 0 S
(29.412 mΩ to OPEN)

Setting accuracy

± (0.5% of set* + 2 A) *set = Vin/Rset

Constant Voltage (CV) mode

Operating range

30 V range

3 V to 30 V

60 V range

6 V to 60 V

Setting range

30 V range

3 V to 30 V

60 V range

6 V to 60 V

Resolution

1 mV

Setting accuracy

± (0.1% of set + 60 mV)

Input current variation

12 mV

Constant Power (CP) mode

Operating range

0 W to 6000 W

Setting range

0 W to 6300 W

Resolution

0.1 W

Setting accuracy

± (1% of set + 60 W)

Voltmeter

Display

0.000 V to 60.000 V

Resolution

0.002 V

Accuracy

± (0.1% of reading + 60 mV)

Ammeter

Display

0.00 A to 400.00 A

Resolution

0.01 A

Accuracy

± (0.3% of reading + 300 mA)

Wattmeter

Display

0.0 W to 6000.0 W

Resolution

0.1 W

Protection function

DC side

Overvoltage protection (OVP), Overcurrent protection (OCP), Overpower protection (OPP),
Overheat protection (OHP), Reverse connection protection (REV), Undervoltage protection (UVP)

AC side

Voltage range error (outside the 170 V-240 V range)

Frequency range error (outside the 45 Hz-65 Hz range)

Open phase (when one of the three phases is missing)

Soft start

Operation mode

CC mode

Selectable time range

20 ms, 50ms, 100 ms, 200 ms

Time accuracy

± (30% of set + 100 μs)

Remote sensing

Compensation voltage

2 V for a single line (The sensing line is switched by a relay.)

Sequence function

Operation mode

CC, CR, CV, CP

Maximum number of steps

256

Step execution time

10 ms to 999 h 59 min

Resolution

10 ms to 1 min

Other functions

Elapsed time display

Measures the time from load on to load off.
Can be set in the range of 1 s to 999 h 59 min 59 s or off.

Auto load off timer

Automatically turns off the load after a specifi ed time elapses.
Can be set in the range of 1 s to 999 h 59 min 59 s or off.

Communication interface

GPIB, RS-232C, and USB interfaces are equipped as standard.

External controls
(J1 connector on the rear
panel)

External voltage (0 to 10 V): CC/CR/CP control

External voltage (0 to 10 V): CV control

External resistance (0 to 10 kΩ): CC/CR/CP control
External resistance (0 to 10 kΩ): CV control
LOAD ON.OFF

TTL level signal

Range selection

Mode selection

Preset memory A/B/C

Trigger input

Pause cancellation (TTL)

Monitor signal output

V MON (voltage)

5 V f.s (30 V range) /10 V f.s (60 V range)

I MON (current)

10 V f.s (30 V range) /5 V f.s (60 V range)

Status signal output

LOAD ON status

On when the load is on.

ALARM status

On when an alarm processing is in progress.

RANGE status

On when the 30 V range is selected.

Trigger signal output

TRIG OUT; BNC terminal on the front side (approx. 4.5 V, 1 ms wide)

General specifi cations

Input voltage range

AC180 V to 220 V (3-phase 3-wire)

Input frequency range

47 Hz to 63 Hz

Power consumption

200 VA (when no load is input)

Maximum regenerated power 5600 VA

Power regeneration effi ciency 85% or more

Dimensions

Width: 430 mm (16.93") / Height: 173 mm (6.81") / Depth: 550 mm (21.65")

Weight

Approx. 43 kg (94.8 lbs.)

Accessories

Manual, DC input terminal covers, etc.

Description

Model name

Specifi cation

Power cable

AC8-4P4M-M6C

3-phase, 4-core, 8mm

2

-wide M6 cable

Parallel operation cable

PC01-PLZ-4W

Flat cable about 300 mm long

Rack mounting bracket

KRB4

EIA (inch)

KRB200

JIS (millimeter)

173

430

MAX195

MAX665

MAX20

550

32.5

31

115

27

4-M4 screw holes including those on the opposite side (maximum depth: 12 mm)

303

50

50

4-M4 screw holes (maximum depth: 6 mm)

40

470

40

Dimensions

(mm)