beautypg.com

Functions, Soft start function, Regenerated power values recognizable at a glance – Atec Kikusui-PLZ6000R User Manual

Page 3: Auto load off timer function, Parallel operation supporting up to 30 kw, Sequence function, Equipped with major interfaces

background image

Regeneration efficiency of PLZ6000R

Load power [W]

Regener

ation efficiency [%]

Power regeneration efficiency of up to 90%

(at rated power)

The use of a proprietary switching technology (patent pending)
provides high power regeneration efficiency - from 85% or
more at one-third of rated power (2000 W) to a maximum of
90% or more.
This energy saving feature greatly reduces the electronic
load's environment impact on your plant and it is not necessary
to equip special cooling system such as water cooling method
to supress the heat generation.

Time

0

Time

0

When the soft start function is not used

When the soft start function is used

Output voltage of the DC power supply
Input current of the electronic load

Output voltage

Output voltage

7 A

Time

100 seconds
RAMP ON (ramp)
7 A

150 seconds
RAMP OFF (step)
7 A

80 seconds
RAMP ON (ramp)
0.5 A

Step 3

Step 1

Step 2

Input current

Time

Voltage

0

V1

V2

V2: Voltage after the specified time elapses
V1: Voltage when UVP is detected

Tcutoff Tcount

Tcount: Elapsed time indicator (Count Time)
Tcutoff: Auto load off timer (Cut Off Time)

R

TIME:

0 0 0 : 0 0 : 0 0

OCP

ACpwr

OPP

220.00

A

0.1500S

-5.3

kW

-30.8

Wh

6600.0

w

C . R

3 0 V - 4 0 0 A

200.00

A

30.000

V

6000.0

W

SET

6.6666

k

The current regenerated power value is shown in the upper row of the section, while
the accumulated regenerated power value is presented in a larger font in the lower row.
(The minus (-) sign indicates power regenerated.)

Functions

Soft start function

In constant current (CC) mode, this function causes the load
current to rise gradually when the initial load is at 0 V while the
load of the load unit is on or when the load of the load unit is
turned on. It allows you to conduct tests under highly realistic
load conditions.
[The soft start time can be selected from the following options -
20, 50, 100, and 200 ms.]

Regenerated power values recognizable at a

glance!

The large-size LCD panel displays regenerated power values
in real time.
This makes the energy saving effect much easier to recognize.

Auto load off timer function

This function automatically turns off the load current; it is
useful for discharge tests of batteries and other devices.
• Measurement of the time elapsed from the start of discharge

until the fi nal voltage (UVP) is detected (elapsed time display)

• Measurement of the closed circuit voltage after the specifi ed

time elapses from the start of discharge (auto load off timer)

Parallel operation supporting up to 30 kW

A large-capacity system of up to 30 kW can be built using a
parallel connection confi guration with one control unit. (The
system may consist of up to fi ve units - one master unit and
four slave units.)

Sequence function

This function automatically executes arbitrarily set sequence
patterns step by step (operation by operation). It enables
various types of waveforms to be simulated. (A maximum of 10
programs can be created, each consisting of up to 256 steps.
Operation modes, ranges, loop counts, etc. can be specifi ed in
these programs.)

ABC preset memories

Three preset memories A, B, and C are provided to store and
read up to three different combinations of an operation mode, a
range, and set values.

Equipped with major interfaces

GPIB, RS-232C, and USB interfaces are equipped as standard,
making it easy to integrate the electronic load into a variety of
testing systems.
Suppor t for these interfaces, coupled with the sequence
function, allows you to build diverse types of system.
(The SCPI commands are adopted.)