Specifi cations, Specifi cations of the main unit, Specifi cations of the communication interface – Atec Kikusui-PCR500 User Manual
Page 4: Dimensions (units: mm)
Specifi cations
Specifi cations of the main unit
Note: “TYP value” indicates a typical value and does not guarantee the performance. "rdng" indicates a reading on the device.
PCR500M
PCR1000M
PCR2000M
Input voltage
Nominal rated input: 100 to 120 V AC/200 to 240 V AC, 50/60 Hz, single phase
Input voltage range: 90 to 132 V AC/180 to 250 V AC (automatically determined when the power
is turned on), 47 to 63 Hz, single phase
Input current
Up to 9 A/4.5 A
Up to 18 A/9 A
Up to 36A/18 A
Input power factor
*
1
0.9 (TYP value)
Effi ciency
At least 70%
Output voltage
1 to 135 V AC/2 to 270 V AC (135 V/270 V range)
1.4 to 190 V DC/2.8 to 380 V DC (135 V/270 V range)
Setting Resolution
0.1 V
Output capacity
AC mode: 500 VA at maximum AC mode: 1000 VA at maximum AC mode: 2000 VA at maximum
DC mode: 400 W at maximum
DC mode: 800 W at maximum
DC mode: 1600 W at maximum
Maximum current
AC mode: 5 A/2.5 A
*
2
AC mode: 10 A/5 A
*
2
AC mode: 20 A/10 A
*
2
DC mode: 4 A/2 A
*
3
DC mode: 8 A/4 A
*
3
DC mode: 16 A/8 A
*
3
Output frequency
Range: 40 to 500 Hz, setting: 0.1 Hz, accuracy: ±2×10
-4
Output waveform distortion ratio 0.5% or less (at 50 V to 135 V/100 V to 270V at load power factor 1)
Accuracy of voltmeter
±(0.5% of rdng + 0.3 V/0.6 V)
(Output voltage greater than 13.5 V/27 V and output frequency 45 Hz to 65 Hz/DC at 23 ± 5°C)
Accuracy of ammeter
(RMS)
±(0.5% of rdng + 0.02 A/0.01 A) ±(0.5% of rdng + 0.04 A/0.02 A) ±(0.5% of rdng + 0.08 A/0.04 A)
(5% to 100% of the maximum output current and output frequency 45 Hz to 65 Hz or DC at 23 ± 5°C)
Dimensions (maximum)
214W × 124 (150)H × 350 (395)D mm 429 (450)W × 128 (150)H × 350 (400)D mm 429 (450)W × 128 (150)H × 450 (500)D mm
Weight
Approximately 6 kg
Approximately 11 kg
Approximately 15 kg
Operating temperature
and humidity range
0 to 40°C, 20%rh to 80%rh (non-condensing)
Storage temperature and
humidity range
-10°C to 60°C, 90%rh or less (non-condensing)
*1 When the output voltage is 100 V/200 V (in the 135 V/270 V range), the current is maximum, and the load power factor is 1.
*2 When the output voltage is 1 V to 100 V/2 V to 200 V. Depends on the power capacity when the output voltage is 100 V to 135 V/200 V to 270 V.
*3 When the output voltage is 1.4 V to 100 V/2.8 V to 200. Depends on the power capacity when the output voltage is 100 V to 190 V/200 V to 380 V.
Specifi cations of the communication interface
RS-232C
Conforms to EIA232D specifi cations. D-SUB9 pin connector.
Baud rate: 1200, 2400, 4800, 9600, 19200 bps
Data length: 8 bits, stop bit: 1 bit, no parity bit, X-Flow contorol
GPIB (IB21: optional)
Conforms to IEEE STD.488.1-1978 specifi cations.
SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E1
USB (US21: optional)
Conforms to USB 2.0 specifi cations.
Conforms to USBTMC-USB488 device class specifi cations.
Communication speed: 12 Mbps (full speed)
Common
Software protocol: IEEE 488.2 STD 1992
Command language: SCPI Specifi cation 1999.0
Analog interface specifi cations (EXO4-PCR-M: optional)
Input terminal
Maximum allowable input voltage
±15 V
Type
BNC
Input impedance
10 kΩ ± 5% (not unbalanced)
Isolation voltage
±100 Vmax
EXT-AC mode
*
1
Input voltage range
0 V to ±10 V (DC)
Voltage amplifi cation rate (135 V/270 V range) 13.5 times or 27 times
Frequency setting range
40 Hz to 500 Hz
EXT-DC mode
Input voltage range
ATT off
0 V to ±1.90 Vpeak (0 to 1.35 Vrms sine wave)
ATT on
0 V to ±10 V (DC)
Input frequency range
ATT off
*
2
40 Hz to 500 Hz (sine wave) /40 Hz to 100 Hz (square wave) /DC
Frequency characteristics
ATT off
– 0.3 dB at 500 Hz with respect to 55 Hz (typical value)
Voltage amplifi cation rate
(135 V/270 V range)
ATT off
100 times or 200 times
ATT on
19 times or 38 times
Output voltage distortion ratio
*
3
Main unit specifi cations + 0.5% or less
*1 ATT is always set to on.
*2 Measurable range for voltage, current and power is DC and from 40 Hz to 500 Hz. The frequency is set based on the input waveform cycle.
*3 In the EXT-AC mode, when direct current is input. In the EXT-DC mode, when a sine wave with 0.1% or less distortion rate is input.
Dimensions (units: mm)
Printed in Japan
Issue:Sep.2011 2011091KSOHEC51
MAX 20
124
MAX 150
214
350
MAX 395
MAX 25
MAX 400
350
429
MAX 15
MAX 450
MAX 150
128
PCR500M
PCR1000M
MAX 500
450
MAX 150
128
MAX 450
MAX 15
429
PCR2000M
MAX 30
MAX 30
■ All products contained in this catalogue are equipment and devices that are premised on use under the supervision
of qualifi ed personnel, and are not designed or produced for home-use or use by general consumers.
■ Specifi cations,
design and so forth are subject to change without prior notice to improve the quality.
■ Product names and prices are
subject to change and production may be discontinued when necessary.
■ Product names, company names and
brand names contained in this catalogue represent the respective registered trade name or trade mark.
■ Colors,
textures and so forth of photographs shown in this catalogue may differ from actual products due to a limited fi delity in
printing.
■ Although every effort has been made to provide the information as accurate as possible for this catalogue,
certain details have unavoidably been omitted due to limitations in space.
■ If you fi nd any misprints or errors in this
catalogue, it would be appreciated if you would inform us.
■ Please contact our distributors to confi rm specifi cations,
price, accessories or anything that may be unclear when placing an order or concluding a purchasing agreement.
■Distributor:
530 Lakeside Drive, Suite#180, Sunnyvale, CA 94085, U.S.A.
Phone : 408-733-3432 Facsimile : 408-733-1814
www.kikusuiamerica.com
1-877-876-2807
www.kikusui.cn
Room, D-01,11F, Majesty Bld, No.138, Pudong Ave, Shanghai City
Phone : 021-5887-9067 Facsimile : 021-5887-9069