SPECIFICATIONS
RATING/DESCRIPTION CONDITION
Type of Stabilizer
Linear/automatic crossover
Voltage/Current
Adjustment
Voltage
0 to 100% E
o
max
Analog or digital, 12 bit
Range
Current
0 to 100% I
o
max
Use menu program
(Source)
0 to 10% I
o
max
to change
(200W models only)
current scale
Current
50% I
o
max (200W)
Fixed value
(Sink)
100% I
o
max (40W)
not calibrated
Programming Voltage
0.025% E
o
max
Current measurement
Resolution
Current
0.025% I
o
max
requires a
calibrated shunt
Programming
Voltage
<0.025% E
o
max
Accuracy
Current
<0.05% I
o
max Both current scales
(200W models)
Data Readback
Voltage
<0.05% E
o
max
Accuracy
Current
<0.05% I
o
max Both current scales
(200W models)
Source Effect
Voltage
<0.001% E
o
max
Input voltage
Current
<0.002% I
o
max
105-125/210-250V a-c
Load Effect
Voltage
<0.005% E
o
max
no load-full load
Current
<0.015% I
o
max
short-full load
Temperature
Voltage
<0.01% E
o
max
Per °C
Effect
Current
<0.02% I
o
max
(0 to 50°C)
Time Effect
Voltage
<0.01% E
o
max
0.5-8.5 hours
Current
<0.02% I
o
max
(5)
Ripple/Noise
Fast Mode
0.002% / 0.02% E
o
max
See Note 6
Slow Mode
0.001% / 0.01% E
o
max
Programming Rise/
Voltage 180
µsec
Fall Time (Fast mode)
Current
200 µsec
See Note 1
Transient Voltage Fast Mode
1 msec
Recovery
Slow Mode
15 msec
See Note 2
Time for
Load Change
Current Fast Mode
500 µsec
Small Signal
Voltage
2.5KHz
See Note 3
3dB Bandwidth
Current
2.3KHz
See Note 4
Slew Rate of the
Voltage
>0.015 x E
o
max V/µsec
Output Voltage
>0.03 x E
o
max V/µsec
High range
(Fast mode)
Current
Overshoot
None
Turn ON/OFF
Remote Sensing Range
0.5V d-c per lead
300V models
d-c
500V models
1KV d-c or p-p plus
Between each
Isolation
1000V models
max. output voltage
output terminal
Voltage
2000V models
0.5KV d-c or p-p plus
and chassis
max. output voltage
Enable/Disable
Local
Front panel keypad
See Note 7
Output Power
Remote
IEEE 488 (GPIB) bus
Output Display
Local 2 x 16 character alphanumeric backlit LCD
Series Connection
Automatic or master-slave
For slave unit, use
operation, limited by the
analog programming
d-c isolation limit voltage only
Parallel Connection
Automatic or master-slave
For slave unit, use
operation analog
programming
only
Note 1: Load = Eo max / Io max. Vout between 0-Eomax.
The programming time is measured between 10% and 90% of Eo max or Io max.
Note 2: Voltage mode, load switched from open circuit to Io max. at Eo = 200V. Current
mode, load switched from short circuit to 200V at Io max.
Note 3: For maximum load (Eo max / Io max) with a d-c bias of 200V set by the keypad
and an analog input sinusoid = 0.2V r ms measured at the analog input terminals.
Note 4: For maximum load (Eo max / Io max) with a d-c current bias = 200 x Io max / Eo
max set by the keypad and an analog input sinusoid = 0.2V r ms measured at the
analog input terminals.
Note 5: 0.05% for BHK 300-0.6MG.
Note 6: With minus terminal grounded, common mode current does not flow through either
the load or the current sensing resistor.
Note 7: 200W models: Acts on digital programming only; 40W models: Versatile output on/off
port (digital/relay contacts) acts on both analog and digital programming.
SIDE VIEW
FRONT VIEW
BHK-MG HALF-RACK MODELS
BHK-MG FULL-RACK MODELS
TOP VIEW
SIDE VIEW
REAR VIEW
8.120
(206.25)
4.860
(123.44)
.250
(6.35)
.112 (2.84)
17 (431.80)
15.90 (403.86)
.250 (6.35)
TOP VIEW
REAR VIEW
Rear
Front
Rear
Front
OUTLINE DIMENSIONAL DRAWINGS
Fractional dimensions in light face type are in inches,
dimensions in bold face type are in millimeters.
Tolerance: ± 1/64" (0.4) between mounting holes,
± 1/32" (0.8) other dimensions
FRONT VIEW
5.218
(132.54)
8.344 (211.94)
A N I S O 9 0 0 1 C O M P A N Y
KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11352 USA • Tel: (718) 461-7000
Fax: (718) 767-1102 • Email: [email protected] •
www.kepcopower.com/bhkmg.htm
BHK-MG OUTPUT CHARACTERISTICS