11 Fluke Corporation Fluke 430 Series Three-Phase Power Quality Analyzers

Mechanical
Size

256 mm x 169 mm x 64 mm (10 in x 6.5 in x 2.5 in)

Weight

2 kg (4.5 lb)

Power
Line power

Switchable 115 V, 230 V adapter with country specific plug

Power adapter output voltage

15 V dc to 23 V dc; use only power adapter BC430

Battery power

Rechargeable NiMH BP190 (installed)

Battery operating time

> 7 hours

Battery charging time

4 hours, 8 hours for/006 version (instrument off)

Power saving

Adjustable time for dimmed backlight with on screen power indicator

Standards
Measurement methods used

IEC 61000-4-30 Class-A

Measurement performance

Fluke 435 IEC 61000-4-30 Class-A, Fluke 434 IEC 61000-4-30 Class-B

Power quality

EN 50160

Flicker

IEC 61000-4-15

Harmonics

IEC 61000-4-7

Cross talk
Between V inputs

-60 dB @ nominal frequency

Voltage to current input

-95 dB @ nominal frequency

Safety
Compliance

IEC/EN 61010-1-2001

CAN/CSA C22.2 No 61010-1-04

UL std No 61010-1

Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, Part 1: General requirements

Rated: 600 V CAT IV/1000 V CAT III Pollution Degree 2

Max voltage on banana input

1000 V CAT III/600 V CAT IV

Max voltage on current BNC input

42 Vpeak

Environmental
Operating temperature

0 °C to +50 °C (32 °F to 122 °F) battery only, 0 °C to +40 °C (32 °F to 104 °F) with adapter,

within spec +15 °C to +35 °C (59 °F to 95 °F)

Storage temperature

-20 °C to +60 °C (-4 °F to +140 °F)

Humidity

10 °C to 30 °C: 95 % RH non-condensing;

30 °C to 40 °C: 75 % RH non-condensing;

40 °C to 50 °C: 45 % RH non-condensing battery only

Maximum operating altitude

3000 m. Derate to 1000 V CAT II/600 V CAT III/300 V CAT IV above 2000 m

Maximum storage altitude

12 km

Warranty

Three-years on mainframe, one-year on included accessories

Printers and Interface
Type

Serial, optically isolated. Compatible with PM9080 (RS-232) or OC4USB (USB)

Baud rate

1200, 2400, 9600 to 115 kB

Print out facility (B&W only)

Via optional adapter PM9080 or PAC 91

Print protocol

Epson FX/LQ, Deskjet, LaserJet , DPU-414 or PostScript

General specifications

cont.

Electro Magnetic Compatibility (EMC)

Emission and immunity

EN61326-1

Fluke 434/435, including standard accessories, conforms with the EEC

directive 89/336 for EMC immunity, as defined by EN61326, with the

addition of the table below

Frequency

Disturbance < 0.5 %

Disturbance < 10 %

80 MHz to 400 MHz

All ranges

400 MHz to 600 MHz

All other ranges

125 V range

600 MHz to 1 GHz

All ranges

The Analyzer is susceptible for RF fields with a field strength of 10 V/m, between 400 MHz and 600 MHz (Performance criteria B).

1

Depending on clamp scaling, volt scaling 1:1

2

50 Hz/60 Hz nominal frequency according to IEC 61000-4-30

3

Add clamp accuracy and phase shift

4

The logger and mains signaling function are optional for the Fluke 434 and

standard on the Fluke 435

5

Measured on reference voltage input A/L1

6

Maximum time 9999 hours

7

Estimated duration

8

Add ±(n-1) x 2.5 ° for amplitude when using i430-flex-4pk