VDS-2002
Voltage Dip and Up Simulator
Fully compliant with all the test generator requirements of IEC standard
One unit solution for dip, swell, interruption, and variation tests up to 16A 290V single phase AC
Interruption test up to 16A 125V DC*
Two motor-driven transformers approach enables switching between any voltages*
Preset IEC test levels 0%/40%/70% additional 120%
Two modes for 0% (interruption) test: open & short*
Optional Windows Application Software available to more extensively control the unit
Accurate waveforms
* Optional software required
FEATURES
CONTROL PANEL
EUT OUTPUT:
receptacles (Multi-type) +Terminal Blocks for AC/DC.
START:
starts the test.
STOP:
stops the test.
LINE:
turns on and off power to the EUT
DIP CYCLES:
selects the duration of a dip among 0.5, 1, 5, 10, 25 and
50 cycles.
DIP PHASE:
selects the phase angle at which a dip starts among 0,
45, 90, 135, 180, 225, 270 and 315 degrees.
REPEAT COUNT:
selects the number of dips among 1, 3, 5, 10, 30, 50,
100 and infinite.
MEMORY NUMBER:
used to save or call up the selected test setting among
preset 5 settings
SW1:
for output verification, the unit outputs the normal
voltage adjusted by the slide transformer 1.
SW2:
for output verification, the unit outputs the dip/swell
voltages adjusted by the slider transformer 2.
INTERVAL CYCLES:
selects the time interval between each dip among 1, 3,
5, 10, 30, 50, 100, 300, 500 cycles and 10s.
TEST LEVEL:
selects a test level among 0, 40, 70 and 120%.