beautypg.com

Atec Haefely-AXOS Series User Manual

Page 9

background image

9

Expandable Test Systems

IEC / EN 61000-4-5 EDITION 2 & UPCOMING EDITION 3 SURGE COMBINATION WAVE
Output voltage

0.2 – 5.0 kV ±10%

Output current

0.1 – 2.5 kA ±10%

Voltage rise time

1.2 µs ±30%

Current rise time 8 µs ±20%

Voltage duration

50 µs ±20%

Current duration 20 µs ±20%

Polarity

postive / negative /
alternate

Integrated single
phase CDN

264 V AC / 16 A
220 V DC / 10 A

Output impedance 2 Ohm
Phase sync

0 – 359° with 1° steps or
asynchronous mode

Impulse trigger

automatic 2 s – 100 min
manual
external trigger input

Counter preselect 1 – 1'000 / infinite
Counter

100'000

Peak voltage
monitor

BNC output: 1000:1
display: 3 digits

Peak current
monitor

BNC output: 1 kA/V
display: 3 digits

IEC / EN 61000-4-11 EDITION 2 AND IEC / EN 61000-4-29 DIPS & INTERRUPTS
Max. voltage

264 V AC/DC

Interrupt time

0.5 period – 800 peri-
ods
100 µs – 1000 minutes

Max. current

16 A AC/DC continuous
20 A for 5 s
23 A for 3 s
40 A for 3 s
> 500 A inrush current

Interval time

1 period – 800 periods
synch
100 µs – 1000 minutes
asynch

Trigger

automatic
manual
external trigger input

Test time

1 s – 1000 minutes
infinite

Interrupt
dip level

0%
0% – 99% with external
voltage source

Phase sync

0 – 359° 16 / 40 / 50 /
60 Hz
asynchronous mode

RMS voltage
monitor

BNC output: 100:1
display: 4 digits

RMS current
monitor

BNC output: 10 A/V
display: 4 digits