beautypg.com

Atec Haefely-AXOS Series User Manual

Page 15

background image

15

Expandable Immunity Test Systems

IEC / EN 61000-4-5 Telecom Wave / ITU K.20, K.21, K.44, K.45
Max. voltage

0.2 - 7.0 kV ± 10%

Source
impedance /
coupling

15 Ohm
40 Ohm
40 Ohm gas arresters

Front time OC

10 µs ± 30%

Outputs

1 x 15 Ohm direct
4 x 40 Ohm direct
4 x 40 Ohm gas arresters

Decay time OC

700 µs ± 20%

Impulse output

Banana connector

Undershoot OC

< 30%

Impulse input

HV connector

Front time SC

5 µs ± 20%

Transitions

V, Polarity

Decay time SC

320 µs ± 20%

Number of
events

1 - 10'000

Undershoot SC

< 30%

Repetition rate

up to 30 / min.

Polarity

Positive / negative /
alternate

Weight

10 kg

IEC / EN 61000-4-12 AND IEEE C62.41 Ring Wave
Max. voltage

0.2 - 7.0 kV ± 10%

Repetition rate

Up to 30 pulses / min

Frequency

100 kHz

Polarity

Positive / negative /
alternate

Rise time OC

0.5 µs

Floating output

Max. 460 V / AC

Rise time SC

1 µs

Phase sync
accuracy

± 1°

Impedance

12 Ohm, 30 Ohm

Damping rate

60% of previous peak

IEC / EN 61000-4-11 EDITION 2 AND IEC / EN 61000-4-29 DIPS & INTERRUPTS
Max. voltage

264 V AC/DC

Interrupt time

0.5 period – 800 periods
100 µs – 1000 minutes

Max. current

16 A AC/DC continuous
20 A for 5 s
23 A for 3 s
40 A for 3 s
> 500 A inrush current

Interval time

1 period – 800 periods
synch
100 µs – 1000 minutes
asynch

Trigger

automatic
manual
external trigger input

Test time

1 s – 1000 minutes
infinite

Interrupt
dip level

0%
0% – 99% with external
voltage source

Phase sync

0 – 359° 16 / 40 / 50 / 60 Hz
asynchronous mode

RMS voltage
monitor

BNC output: 100:1
display: 4 digits

RMS current
monitor

BNC output: 10 A/V
display: 4 digits