Atec Pacific-Power-M6204 User Manual
M6204 iec flicker impedance, Iec flicker impedance, The leader in ac power technology
IEC Flicker Impedance
M6204 IEC Flicker Impedance
The M6204 unit provides the requisite lumped impedance between the AC Power
Source and the Unit Under Test (UUT) used to test for flicker compliance to IEC 61000-
3-3. Designed to meet IEC 60725 - Consideration of reference impedances and public
supply network impedances for use in determining the disturbance characteristics of
electrical equipment having a rated current ≤75 A per phase – the M6204 simulates
the typical public utility impedance characteristics found in most European countries
in order to provide a common flicker measurement reference.
IEC Flicker Impedance
Standard Features:
•
Three Phase Flicker Impedance Network
Supports both single and three phase
flicker testing of UUT’s up to 16Arms per
phase
•
Z
ref
Impedances Values per IEC 60725
Line Impedance: 0.24 Ω+ 0.15 j Ω
Neutral Impedance:
0.16 Ω + 0.10j Ω
•
Compatible with 360AMXT and 3120AMXT
AC Source Models
IEC Impedance is matched to AC Source
Output impedance for exact IEC 60725
matching
•
High Qualify Impedance Components Used
Low Thermal Drift and Forced Air Cooling
while under Load Ensures Constant Flicker
Impedance during Long Flicker Test Runs
•
Dual Connectors on Rear Panel
Multiple Terminal Blocks Provided for
Power, Voltage Sense and Power Analyzer
Connections Simplifies Connections
•
Standard 19” Rack Mount Enclosure
Fits easily on Lab Bench, on top of the AC
Power Source used or in an Instrument
Cabinet
Standards Supported:
•
IEC 61000-3-3 / EN 61000-3-3
•
IEC 61000-4-13 / EN 61000-4-13
•
IEC 61000-4-27/ EN 61000-4-27
•
IEC 60725
T H E P O W E R O F E X P E R T I S E
The Leader in AC Power Technology
FREQUENCY CONVERSION
R & D
MANUFACTURING
AEROSPACE
MILITARY
CUSTOM
A separate impedance network in the Neutral leg ensures full compliance to IEC
61000-3-3 and IEC 60725 even under imbalanced three phase load conditions. The
same three phase Impedance network is also fully capable of supporting single
phase Flicker test. In this case, the Phase A impedance and Neutral impedance
combine together to provide the required Z
ref
= 0.40 Ω + 0.25 j Ω single phase
impedance.
Three Phase and Single Phase UUT Testing
The use of high quality components with low thermal drift and high saturation
resistance ensures a stable impedance network throughout the entire flicker test
duration – typically two hours. This is augmented by efficient yet quiet forced
air cooling. Testing to the full 16 Arms per phase as required for products that
fall under the IEC 61000-3-3 Flicker Standard is fully supported by this lumped
impedance with ample margin for temporary overload conditions.
Full 16 Arms per Phase Capable
AC Source Matched
An early pioneer in the development solid-state power conversion equipment,
Pacific Power Source continues to develop, manufacture, and market both linear
and high-performance PWM AC Power Sources. Pacific’s reputation as a market
and technology leader is best demonstrated by its continuing investments in
both research and development and world-wide customer support. With corpo-
rate owned offices in the United States, Germany, the United Kingdom, and China,
local personalized support is always available.
12KVA
Three Phase
16 Arms/Phase
IEC 60725 Compliant
The M6204 impedance is factory calibrated and matched to the AMX AC Power
Source Model it is used with. This ensures that the combination of AC Source
Output Impedance and Lumped Impedance adds up to the requisite IEC 60725
Impedance values. This prevents unwanted system level errors that can occur
when the IEC Flicker Impedance is sourced from a different vendor as the AC
Power Source.