5

METRISO 5000 D-PI

Digital High-Voltage Insulation Tester

Features and Accessories for High-Voltage Tests

Features B1 (PROFITEST 204HP-2.5kV) and B2 (204HV-5.4kV)
Expanded features for high-voltage tests

Test voltage selectable in 50 V steps

Rise time (ramp) adjustable from 0.1 to 99 s

Test duration adjustable from 1 to 120 s

Floating test voltage outputs

Electronically controlled test sequence

Test sequence can be started with test pistol

Breakdown voltage display

Pulse-arc operation

Phase angle display

Measured values can be saved to memory

Acoustic and optical error messages

Key switch for protection against unauthorized start-up

Connector terminals for external signal lamps

Features B1 (PROFITEST 204HP-2.5kV)

Voltage test per EN 60204 / VDE 0113

Test power: 500 VA (intermittent)

Breaking current adjustable in 1 mA steps

Features B2 (PROFITEST 204HV-5.4kV)

Test power: 50 VA

Breaking current adjustable in 0.5 mA steps

The respective high-voltage module which is supplied ex works
firmly attached to the METRISO 5000 D-PI basic instrument (i.e. it
cannot be removed or subsequently fitted be the user) is intended
for high-voltage testing.
Voltage, current and phase angle can be measured via fixed mea-
suring cables.

Technical Data PROFITEST 204HP-2.5kV

Technical Data PROFITEST 204HV-5.4 kV

Feature D: Trolley Caddy 204

Trolley for basic instrument
combined with high-voltage
module, includes cover with
side pockets.

Feature F1: Signal 204

Signal lamp set mounted
to a magnetic base for
indicating high-voltage
testing in accordance with
DIN VDE 0104.

Accessory: Claim 204

Set of various items used
to warn unauthorized per-
sons and for securing
large areas, machines or
machine components
during the performance of
high-voltage testing.

Nominal Range
of Use

Resolu-
tion

Measuring
Uncertainty

Intrinsic
Uncertainty

Test Voltage
U AC

250 V

 2.5 kV

1 V

10 V

(5% rdg. + 5 d)

(2.5% rdg. + 5 d)

Meas.
Quantity

Current
I AC

10.0

 200 mA 0.1 mA

1 mA

(7% rdg.+ 5 d)

(5% rdg. + 5 d)

Nominal Range
of Use

Resolu-
tion

Measuring
Uncertainty

Intrinsic
Uncertainty

Test Voltage
U AC

650 V

1.00 kV

1.00 kV

5.35 kV

1 V

10 V

+2

 –7% rdg.

+2

 –5% rdg.

0

 –5% rdg.

0

 –3% rdg.

Meas.
Quantity

Current
I AC

1.0

 10.0 mA 0.01 mA

0.1 mA

(7 % rdg.+ 5 d)

(5 % rdg. + 5 d)