Model smrt36 – Atec Megger-SMRT36 User Manual
Page 7
7
SMRT36
Megger Relay Test System
ORDERING INFORMATION
Model SMRT36 -
Voltage/Current Modules
Enter 1, 2 or 3
Base Unit Options
N = No Extra Binary I/O
P = Plus Binary I/O & Battery Simulator
Common Returns Option
F = Floating Ungrounded Common Return
G = Grounded Common Returns
C = CE Mark, 220-240V Input, Floating
E = CE Mark, 220-240V Input, Grounded
Bluetooth Option
1 = With Bluetooth
0 = Without
Test Leads Option
1 = With Leads
0 = Without Leads
Hardware Options
S = Standard unit
T = Transducer
IEC61850 Option
1 = With IEC 61850 GOOSE
0 = Without
Power Cord Option
A = North American Power Cord
I
= International Power Cord
E = Continental Europe Power Cord
U = United Kingdom
Reserved for Future Use
0
STylE NuMBER IDENTIFICATION
DESCRIpTIONS OF HARDWARE OpTIONS
Voltage/Current Module: The SMRT36 unit can have up to a total
of 3 voltage/current modules. Enter the number of desired Voltage /
Current modules 1, 2 or 3.
Future: 0, Reserved for future use.
Base Unit Options: The first two channels provide 1 binary input
and 1 binary output each. Enter N for No extra binary I/O or battery
simulator. For the user who requires the extra binary inputs, outputs
and/or the battery simulator enter P for Plus option.
Smart Touch View Interface Option: Enter the number 1 for the
unit to come with the STVI, or enter the number 0 for without.
Common Returns Option: The floating returns option provides
independent, isolated return terminals for each output channel.
The grounded common returns option, the return terminals are
interconnected internally and connected to chassis ground. The CE
Mark C and E units are designed to operate with an input voltage of
220 to 240 Volts. The F and G units are designed to operate with an
input of 100 to 240 V.
Bluetooth Option: For customers, who wish to have a wireless
control of the SMRT unit, enter the number 1 for the unit to come
with the Bluetooth option, or enter 0 for without.
Power Cord Option: Customers can choose which type of power
cord they want the unit to come with.
• A Option – NEMA 5-15 to IEC60320 C13 connectors,
UL & CSA approved for countries with NEMA outlets.
• I Option - International color coded wires (light blue, brown and
green with yellow stripe) insulation jacket stripped ready for male
connector with IEC 60320 C13 connector.
CE marked.
• E Option - CEE 7/7 “Schuko” plug to IEC 60320 C13 connector
is CE marked.
• U Option - United Kingdom power cord with IEC 60320 C13
connector, and 13 Amp fuse. CE Marked.
Bluetooth Option: For customers who wish to have a wireless
control of the SMRT unit, enter the number 1 for the unit to come
with the Bluetooth option installed. Enter 0 for without.
IEC 61850 Option: The SMRT36 in conjunction with the Megger
GOOSE Configurator (MGC) software can be used in the testing
or commissioning of IEC 61850 compliant devices. In order for the
SMRT36 to be able to subscribe as well as publish GOOSE messages,
the IEC 61850 feature needs to be enabled. Enter the number 1 for
the unit to come with the IEC 61850 option enabled. Enter 0 for the
unit without IEC 61850 enabled.
Smart Touch View Interface Option
1 = With STVI;
0 = Without
DESCRIpTION OF SOFTWARE OpTIONS
Included Software
part Number
AVTS Basic with STVI Application CD
81302
Software Options
AVTS Basic with IEC 61850 Megger GOOSE Configurator, and STVI Application CD
1002-103
AVTS Advanced with STVI Application CD
81570
AVTS Advanced Test with IEC 61850 Megger GOOSE Configurator, and STVI Application CD
1001-106
AVTS Professional with STVI Application CD
81571
AVTS Professional Test with IEC 61850 Megger GOOSE Configurator, and STVI Application CD
1002-102