The SMRT current amplifier provides a unique flat power curve from
4 to 30 Amperes per phase to permit testing of electromechanical
high impedance relays, and other high burden applications, with an
extended operating range up to 60 Amperes at 300 VA rms.

AC Voltage Output

Outputs are rated with the following Ranges:
Output Volts

Power

Max I

30 Volts

150 VA

5 Amps

150 Volts

150 VA

Variable

2

300 Volts

150 VA

0.5 Amps

DC 150 Watts
Duty Cycle: Continuous

With two voltages in series

The output voltage and power doubles to provide 600 volts at
300 VA.

"powerV" Voltage Amplifier Output power Curves

“powerV

TM

” Voltage Amplifier - Extended power Range

The SMRT voltage amplifier provides a flat power curve from 30
to 150 Volts in the 150V range to permit testing of high current
applications such as panel testing.

Voltage Amplifier in Current Mode:

The voltage amplifier is convertible to a current source with the
following output capability. Output power ratings are specified in
rms values and peak power ratings.
Output Current

Power

Max V

Duty Cycle

5 Amperes

150 VA

30.0 Vrms

Continuous

(212 peak)

15 Amperes

120 VA

8.0 Vrms

90 Cycles

phase Angle

Ranges: 0.00 to 359.99 degrees, Counter Clock Wise, or Clock
Wise rotation, or 0.00 to ±180.00 degrees
Accuracy: ±0.02° typical, ±0.25° max at 50/60 Hz

1

Megger reserves the right to change product specifications at any time.

2

PowerV

TM

voltage amplifier output current varies depending on the voltage setting on the 150 Volt range, see curve.

SpECIFICATIONS

1

Input power

The input voltage rating varies depending upon the style number.
Universal units, the input voltage may be from 100 to 240 VAC,
± 10%, 50/60 Hertz. CE Marked units, the input voltage may be
from 220 to 240 VAC, ± 10%, 50/60 Hertz. Total maximum output
power will be limited for CE marked units . Input current required
varies with the number of output modules in use, load, and input
voltage value. With three VIGENS, the maximum input power is
1800VA.

Outputs

All outputs are independent from sudden changes in mains voltage
and frequency, and are regulated so changes in load impedance do
not affect the output. All amplifier outputs are isolated or floating.
The SMRT units can be ordered with the amplifier common returns
tied to chassis ground as an option.

Output Current Sources

The SMRT36 with three VIGEN modules can provide up to
six current sources; three high current/high power, and three
convertible channels providing lower current/high power. The per
channel output current and power ratings are specified in AC rms
values and peak power ratings.
Output Current

Power

Max V/Duty Cycle

1 Ampere

15 VA

15.0 Vrms Continuous

4 Amperes

200 VA (282 peak) 50.0 Vrms Continuous

15 Amperes

200 VA (282 peak) 13.4 Vrms Continuous

30 Amperes

200 VA (282 peak) 6.67 Vrms Continuous

60 Amperes

300 VA (424 peak) 5.00 Vrms 90 Cycles

DC 200 Watts

With three currents in parallel:

Output Current

Power

Max V/Duty Cycle

12 Amperes

600 VA (848 peak) 50.0 Vrms Continuous

45 Amperes

600 VA (848 peak) 13.4 Vrms Continuous

90 Amperes

600 VA (848 peak) 6.67 Vrms Continuous

180 Amperes

900 VA (1272 peak) 5.00 Vrms 90 Cycles

Current Amplifier Output power Curve

With two currents in series:

The compliance voltage doubles to provide 4.0 Amperes at 100
Volts rms.